search
cart
facebook instagram twitter linkedin youtube
  • Sign In
  • Create Account
  • Sign Out
  • My Account
  • NEWS
  • PRODUCTS
    • FEATURED PRODUCTS
  • CONTRACTORS
    • BATH & KITCHEN PRO
    • BUSINESS MANAGEMENT
    • HIGH EFFICIENCY HOMES
    • TECHNOLOGY
    • WATER TREATMENT
    • PMC COLUMNS
      • Dave Yates: Contractor’s Corner
      • John Siegenthaler: Hydronics Workshop
      • Kenny Chapman: The Blue Collar Coach
      • Matt Michel: Service Plumbing Pros
      • Scott Secor: Heating Perceptions
  • ENGINEERS
    • CONTINUING EDUCATION
    • DECARBONIZATION | ELECTRIFICATION
    • FIRE PROTECTION
    • GEOTHERMAL | SOLAR THERMAL
    • PIPING | PLUMBING | PVF
    • PME COLUMNS
      • Christoph Lohr: Strategic Plumbing Insights
      • David Dexter: Plumbing Talking Points
      • James Dipping: Engineer Viewpoints
      • John Seigenthaler: Renewable Heating Design
      • Lowell Manalo: Plumbing Essentials
      • Misty Guard: Guard on Compliance
  • RADIANT & HYDRONICS
    • RADIANT COMFORT REPORT
    • THE GLITCH & THE FIX
  • INSIGHTS
    • CODES
    • GREEN PLUMBING & MECHANICAL
    • PROJECT PROFILES
    • COLUMNS
      • Codes Corner
      • Kristen R. Bayles: Editorial Opinion
      • Guest Editorial
    • SPONSOR INSIGHTS
  • MEDIA
    • EBOOKS
    • PODCASTS
    • VIDEOS
    • WEBINARS
  • RESOURCES
    • BIG BOOK DIRECTORY
    • REP LOCATOR
    • INDUSTRY CALENDAR
    • PM BOOKSTORE
    • CE CENTER
    • MARKET RESEARCH
    • CLASSIFIEDS
  • EMAGAZINE
    • EMAGAZINE
    • ARCHIVE ISSUES
    • CONTACT
    • ADVERTISE
    • PME EMAGAZINE ARCHIVES
  • SIGN UP!
Radiant & HydronicsThe Glitch & The Fix

Been There, Done That

By John Siegenthaler, P.E.
March 15, 2009
When floor heating and domestic water heating occurred at the same time, I discovered there was no flow through the heat exchanger in the indirect tank.

The Glitch


The Glitch

Overview: Many years ago (when I knew enough about hydronics to be dangerous) I put together a system to provide radiant floor heating and domestic water heating for a building addition.

The original building was heated by a well-oversized steam boiler. That boiler had two “bays” for tankless coil water heaters. Not wanting to intermingle the water in the old steam boiler with that in the new system, I installed a very compact tankless coil in the steam boiler, and used it as an isolated heat source for the new system as shown. With the boiler maintaining a minimum temperature of 160 degrees F, and climbing to around 215 degrees F during the steam cycle, this coil had plenty of capacity to handle the new load.

The floor heating portion of the system worked well. It used a high head circulator to provide flow through several thousand feet of PEX tubing. The system also did a good job of heating domestic water. However, if floor heating and domestic water heating occurred at the same time, I discovered there was no flow through the heat exchanger in the indirect tank.

I assumed the small circulator supplying the indirect heater was defective, so I opened it up for a look and test. It was clean and operated fine. After putting it back in the system the problem persisted.

Exercise: So, with the small circulator running, why was there no flow through the heat exchanger in the water heater? Can you figure out what was happening? Also, can you spot some other details in the schematic that should be changed?

What happens when both circulators operate

The Fix

This one took some head scratching. What we eventually found was that the pressure differential created by the high head circulator supplying the radiant portion of the system "

The piping fix

We corrected the situation by rewiring the indirect water heater to operate as a priority load (i.e., the easier fix). However, using a hydraulic separator as shown in the fix drawing could have eliminated this interference. A separate circulator would provide flow through the boiler. The pressure differential created by this circulator would be isolated from the two distribution circulators. The latter would also be isolated from each other by the hydraulic separator in combination with the “short and fat” headers.

The moral of the story: When big circulators and small circulators can “see” each other (e.g., each can sense the pressure differential created by the other) they will “fight”. If the heat source and common piping produce high flow resistance, the fight will be intense, and the big circulator will win every time. Stop the fights – provide hydraulic separation of circuits.

Other changes in the fix drawing include:
  • Adding purging valves on the return side of each load circuit
  • Moving the expansion tank connection point near the bottom of the hydraulic separator
  • Eliminate the original “bullhead tees” between the flow checks
  • Putting the flow check valves on the supply side of each load circuit to help minimize heat migration


Links

  • Hydronic Symbol Legend
  • The Glitch & The Fix - March 2009

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

John siegenthaler 200x200

John Siegenthaler, P.E., is a consulting engineer and principal of Appropriate Designs in Holland Patent, New York. In partnership with HeatSpring, he has developed several online courses that provide in-depth, design-level training in modern hydronics systems, air-to-water heat pumps and biomass boiler systems. Additional information and resources for hydronic system design are available on Siegenthaler’s website,  www.hydronicpros.com.

Recommended Content

JOIN TODAY
to unlock your recommendations.

Already have an account? Sign In

  • 2025 Next Gen ALL-STARS hero 1440

    2025 Next Gen All Stars: Top 20 Under 40 Plumbing Professionals

    This year’s group of NextGen All-Stars is full of young...
    Plumbing & Mechanical Contractor
    By: Kristen R. Bayles
  • Worker using the Milwaukee Tool SWITCH PACK drain cleaner

    Pipeline profits: Drain cleaning, pipe inspection create opportunities

    Drain cleaning and inspection services offer lucrative...
    Plumbing News
    By: Nicole Krawcke
  • Uponor employee, Arturo Moreno

    The reinvestment in American manufacturing and training

    Plumbing & Mechanical Chief Editor Nicole Krawcke and...
    Plumbing News
    By: Natalie Forster and Nicole Krawcke
Manage My Account
  • Newsletters
  • Online Registration
  • Subscription Customer Service
  • eMagazine
  • Manage My Preferences

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to the Plumbing & Mechanical audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of Plumbing & Mechanical or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • HyperPure® PE-RT tubing
    Sponsored byLegend

    More Than One Right Answer: Rethinking PE-RT in Modern Plumbing Systems

Popular Stories

An infographic with "Water Heater Shipment Data" over a chart.

AHRI Data Shows Water Heater Shipments Remain Soft in 2026

Two firefighters in front of a firetruck.

From Firehouse to Jobsite: A Contractor's Approach to Water Heater Replacement

Top 40 Under 40 Next Gen All-Stars Logo

Top 40 Under 40 Next Gen All-Star Competition Officially Open

Download the FREE 2025 Water Conservation, Quality & Safety eBook

Events

August 4, 2026

Is Contractor Training a Cost Center or Your Most Overlooked Growth Engine?

In this webinar, you’ll learn how to reframe training as a measurable revenue driver by connecting contractor performance improvements to real business outcomes—like increased equipment sales, stronger margins, and greater share-of-wallet.

View All Submit An Event

Poll

Getting your new hire jobsite-ready

How long does it typically take to get a new hire jobsite-ready?
View Results Poll Archive

Products

The Water Came To A Stop

The Water Came To A Stop

See More Products
eBook | 2025 Radiant & Hydronics All Stars

Related Articles

  • 01 PM 0923 CLMN John Siegenthaler

    There are still viable applications for solar thermal technology

    See More
  • Siegenthaler: There's no such thing as 'head pressure'

    See More
  • eBook Vol 4.jpg

    Modern Hydronics Done Right Volume 4

    See More

Related Products

See More Products
  • howcome.gif

    How Come? Hydronic heating questions we've been asking for 100 years (with straight answers!)

  • Plumbing Technology, Design & Installation

  • 51CHeeKvw4L._SX322_BO1,204,203,200_.jpg

    Hydronic Radiant Heating: A Practical Guide for the Nonengineer Installer

See More Products
×

Keep your content unclogged with our newsletters!

Stay in the know on the latest plumbing & piping industry trends.

JOIN TODAY!
  • RESOURCES
    • Advertise
    • Contact Us
    • Directories
    • Store
    • Want More
    • Supply House Times
  • SIGN UP TODAY
    • Create Account
    • eMagazine
    • Newsletter
    • Customer Service
    • Manage Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing