search
cart
facebook instagram twitter linkedin youtube
  • Sign In
  • Create Account
  • Sign Out
  • My Account
  • NEWS
  • PRODUCTS
    • FEATURED PRODUCTS
  • CONTRACTORS
    • BATH & KITCHEN PRO
    • BUSINESS MANAGEMENT
    • HIGH EFFICIENCY HOMES
    • TECHNOLOGY
    • WATER TREATMENT
    • PMC COLUMNS
      • Dave Yates: Contractor’s Corner
      • John Siegenthaler: Hydronics Workshop
      • Kenny Chapman: The Blue Collar Coach
      • Matt Michel: Service Plumbing Pros
      • Scott Secor: Heating Perceptions
  • ENGINEERS
    • CONTINUING EDUCATION
    • DECARBONIZATION | ELECTRIFICATION
    • FIRE PROTECTION
    • GEOTHERMAL | SOLAR THERMAL
    • PIPING | PLUMBING | PVF
    • PME COLUMNS
      • Christoph Lohr: Strategic Plumbing Insights
      • David Dexter: Plumbing Talking Points
      • James Dipping: Engineer Viewpoints
      • John Seigenthaler: Renewable Heating Design
      • Lowell Manalo: Plumbing Essentials
      • Misty Guard: Guard on Compliance
  • RADIANT & HYDRONICS
    • RADIANT COMFORT REPORT
    • THE GLITCH & THE FIX
  • INSIGHTS
    • CODES
    • GREEN PLUMBING & MECHANICAL
    • PROJECT PROFILES
    • COLUMNS
      • Codes Corner
      • Natalie Forster: Editorial Opinion
      • Guest Editorial
  • MEDIA
    • EBOOKS
    • PODCASTS
    • VIDEOS
    • WEBINARS
  • RESOURCES
    • INDUSTRY CALENDAR
    • DIRECTORIES
    • PM BOOKSTORE
    • CE CENTER
    • MARKET RESEARCH
    • CLASSIFIEDS
  • EMAGAZINE
    • EMAGAZINE
    • ARCHIVE ISSUES
    • CONTACT
    • ADVERTISE
    • PME EMAGAZINE ARCHIVES
  • SIGN UP!
Columns

What can you do to affect the performance of your heating systems?

More power.

By Ray Wohlfarth
April 22, 2014

“Star Trek” has always been one of my favorite TV series and collection of movies. I like when Captain Kirk pleads with the chief engineer Scotty for more power. While we may not have to jettison and explode our warp core to get more power, there could be things we do that affect the performance of our heating systems.

I am reminded of a call I received during a bitter cold snap. When I answered the telephone, I was told, “Your boilers aren’t working. There is something wrong with them.”

The person on the other end of the telephone call was the director of maintenance for a nursing home where we sold three boilers about four years before. He informed me that he had even raised the boiler temperature setting from 180° F to 200° but the perimeter rooms in the building were cold. He also told me they were going to have to evacuate the facility if we couldn’t come up with something quickly. My service technician was close and I dispatched him to the site.

The technician called and verified the boilers were indeed at 200° and the outer perimeter of the building was cold and the seniors were freezing. The distribution system used a main air-handling unit that sent 60° air to the building. It had hydronic reheat coils to raise the temperature in the rooms, if needed.

My technician said the owner had opened all the balancing valves for the reheat coils in an attempt to get more heat, without success. My technician was at a loss about what to do. Upon questioning, my technician informed me the heating loop ?T or temperature drop was at 3°.

He asked if the system could be undersized and I assured him it was not. I explained that if it was undersized, the water temperature would not be at 200° and the ?T would not be so close. Most systems are designed for a 20° ?T. The low temperature drop made me realize the piping was not surrendering its heat to the building. It must be something in the distribution end.

When he asked what to do, I was stumped and suggested he try closing the balancing valves on the reheat coil until it gets a 20° drop across the coil. Both he and the director of maintenance were skeptical. He called back in a couple minutes and said the discharge and room temperatures had miraculously risen. They changed all the coil balance valves for the same temperature drop and the building heated to the setting of the thermostats. They reduced the boiler temperature back to the proper setting of 180°.

One of the things I have learned about this industry is that no matter how much you think you know, things can still surprise and humble you; that is what I love about it. I did some research on the nursing home situation and found it is not a rare phenomenon. If the velocity of the water through the pipe or coil is excessive, it will not surrender its heat, resulting in comfort complaints. It does not make sense but I have seen it happen.

 

Open zone valves

On a similar project, we were called to an apartment building with fin-tube radiation where residents in several suites were complaining of inadequate heating. The system had an enormous circulating pump that was pumping the hot water to the apartments. The piping system had about 10 zone valves on the returns from the apartments.

When we arrived, the system sounded like a cat howling. Several of the zone valves were closed. When I manually opened the zone valves, the howling went away and the apartments that did not have heat were suddenly heating. We also noticed the fin-tube radiation enclosure had a manual damper that was almost closed on top.

I opened all the dampers wide and felt the heat convection immediately. I also instructed the tenants that couches and chairs in front of the radiation would impede the heat to circulate and should be moved. They refused, saying the furniture would not work anywhere but where they had placed it.

The last building had a combination boiler with an internal copper coil that was used for the domestic hot water for the facility. The boiler was warm but would not heat the domestic water loop. The domestic water side had primary-secondary piping. We partially closed the globe valve on the domestic water coil until the temperature increased. Once the temperature rose, the loop started heating. The client was happy and so were the people in the shower.

If the system is not heating with wide open valves, perhaps it is time to try closing them. Check the temperature drop across the loop. Most systems were designed for a 20° drop. If it is less than that, the system may not be giving up its heat. This domestic water boiler was designed for a 100° rise.

The charts (see link below for the article in pdf form) show some rules of thumb that you can use for verifying the size on hydronic systems for steel pipe (Chart 1), copper tubing (Chart 2) and PEX tubing (Chart 3) based on a 20° ?T.

 

To read the full pdf article please click here.


HELPFUL LINKS:

  • Contact Us
  • Follow PM on Twitter!
  • Find PM on Facebook!
  • Join PM on LinkedIn! 

“Star Trek” has always been one of my favorite TV series and collection of movies. I like when Captain Kirk pleads with the chief engineer Scotty for more power. While we may not have to jettison and explode our warp core to get more power, there could be things we do that affect the performance of our heating systems.

I am reminded of a call I received during a bitter cold snap. When I answered the telephone, I was told, “Your boilers aren’t working. There is something wrong with them.”

The person on the other end of the telephone call was the director of maintenance for a nursing home where we sold three boilers about four years before. He informed me that he had even raised the boiler temperature setting from 180° F to 200° but the perimeter rooms in the building were cold. He also told me they were going to have to evacuate the facility if we couldn’t come up with something quickly. My service technician was close and I dispatched him to the site.

The technician called and verified the boilers were indeed at 200° and the outer perimeter of the building was cold and the seniors were freezing. The distribution system used a main air-handling unit that sent 60° air to the building. It had hydronic reheat coils to raise the temperature in the rooms, if needed.

My technician said the owner had opened all the balancing valves for the reheat coils in an attempt to get more heat, without success. My technician was at a loss about what to do. Upon questioning, my technician informed me the heating loop ?T or temperature drop was at 3°.

He asked if the system could be undersized and I assured him it was not. I explained that if it was undersized, the water temperature would not be at 200° and the ?T would not be so close. Most systems are designed for a 20° ?T. The low temperature drop made me realize the piping was not surrendering its heat to the building. It must be something in the distribution end.

When he asked what to do, I was stumped and suggested he try closing the balancing valves on the reheat coil until it gets a 20° drop across the coil. Both he and the director of maintenance were skeptical. He called back in a couple minutes and said the discharge and room temperatures had miraculously risen. They changed all the coil balance valves for the same temperature drop and the building heated to the setting of the thermostats. They reduced the boiler temperature back to the proper setting of 180°.

One of the things I have learned about this industry is that no matter how much you think you know, things can still surprise and humble you; that is what I love about it. I did some research on the nursing home situation and found it is not a rare phenomenon. If the velocity of the water through the pipe or coil is excessive, it will not surrender its heat, resulting in comfort complaints. It does not make sense but I have seen it happen.

 

Open zone valves

On a similar project, we were called to an apartment building with fin-tube radiation where residents in several suites were complaining of inadequate heating. The system had an enormous circulating pump that was pumping the hot water to the apartments. The piping system had about 10 zone valves on the returns from the apartments.

When we arrived, the system sounded like a cat howling. Several of the zone valves were closed. When I manually opened the zone valves, the howling went away and the apartments that did not have heat were suddenly heating. We also noticed the fin-tube radiation enclosure had a manual damper that was almost closed on top.

I opened all the dampers wide and felt the heat convection immediately. I also instructed the tenants that couches and chairs in front of the radiation would impede the heat to circulate and should be moved. They refused, saying the furniture would not work anywhere but where they had placed it.

The last building had a combination boiler with an internal copper coil that was used for the domestic hot water for the facility. The boiler was warm but would not heat the domestic water loop. The domestic water side had primary-secondary piping. We partially closed the globe valve on the domestic water coil until the temperature increased. Once the temperature rose, the loop started heating. The client was happy and so were the people in the shower.

If the system is not heating with wide open valves, perhaps it is time to try closing them. Check the temperature drop across the loop. Most systems were designed for a 20° drop. If it is less than that, the system may not be giving up its heat. This domestic water boiler was designed for a 100° rise.

The charts (see link below for the article in pdf form) show some rules of thumb that you can use for verifying the size on hydronic systems for steel pipe (Chart 1), copper tubing (Chart 2) and PEX tubing (Chart 3) based on a 20° ?T.

 

Kristin—Please add a link to the pdf.

 

HELPFUL LINKS:

http://www.pmmag.com/contactus Contact Us

https://twitter.com/PnMmag Follow PM on Twitter!

https://www.facebook.com/PMmagazine Find PM on Facebook!

http://www.pmmag.com/linkedin Join PM on LinkedIn!

KEYWORDS: boilers heating systems

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

Ray Wohlfarth is the author of “Lessons Learned in a Boiler Room: A common-sense approach to servicing and installing commercial boilers.” In his spare time, he is president of Fire & Ice in Pittsburgh, Pa. Ray writes a monthly newsletter on commercial boilers. He can be reached at 412/343-4110.

Recommended Content

JOIN TODAY
to unlock your recommendations.

Already have an account? Sign In

  • 2025 Next Gen ALL-STARS hero 1440

    2025 Next Gen All Stars: Top 20 Under 40 Plumbing Professionals

    This year’s group of NextGen All-Stars is full of young...
    Plumbing & Mechanical Contractor
    By: Kristen R. Bayles
  • Worker using the Milwaukee Tool SWITCH PACK drain cleaner

    Pipeline profits: Drain cleaning, pipe inspection create opportunities

    Drain cleaning and inspection services offer lucrative...
    Green Plumbing and Mechanical
    By: Nicole Krawcke
  • Uponor employee, Arturo Moreno

    The reinvestment in American manufacturing and training

    Plumbing & Mechanical Chief Editor Nicole Krawcke and...
    Plumbing News
    By: Nicole Krawcke and Natalie Forster
Manage My Account
  • eNewsletters
  • Online Registration
  • Subscription Customer Service
  • eMagazine
  • Manage My Preferences

More Videos

Popular Stories

Hot water pipes

Campus shutdown at Oakland University exposes hidden risks of aging hot-water infrastructure

Floor heating manifold cabinet with flowmeter and PEX pipe.

Elegance extended: How to use the homerun system of connecting heat emitters

Industrial pressure gauge on a tank.

From cutting edge to classic: How to modernize outdated pneumatic control systems

Poll

Will business be up or down in 2025?

Do you anticipate business in 2025 to be up or down in comparison to 2024?
View Results Poll Archive

Products

The Water Came To A Stop

The Water Came To A Stop

See More Products
eBook | 2025 Radiant & Hydronics All Stars

Related Articles

  • Have you read the installation manual?

    See More
  • 10 reasons why boilers are still excellent heating systems

    See More
  • Can the boiler breathe?

    See More

Related Products

See More Products
  • Greening Steam: How to Bring 19th-Century Heating Systems into the 21st Century (and save lots of green!)

  • Classic Hydronics - How To Get The Most From Those Older Hot-Water Heating Systems

  • what hydronics taught holohan.jpg

    What Hydronics Taught Holohan: A Memoir of Life in the Heating Industry

See More Products
×

Keep your content unclogged with our newsletters!

Stay in the know on the latest plumbing & piping industry trends.

JOIN TODAY!
  • RESOURCES
    • Advertise
    • Contact Us
    • Directories
    • Store
    • Want More
    • Supply House Times
  • SIGN UP TODAY
    • Create Account
    • eMagazine
    • eNewsletter
    • Customer Service
    • Manage Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2025. All Rights Reserved BNP Media.

Design, CMS, Hosting & Web Development :: ePublishing