search
cart
facebook instagram twitter linkedin youtube
  • Sign In
  • Create Account
  • Sign Out
  • My Account
  • NEWS
  • PRODUCTS
    • FEATURED PRODUCTS
  • CONTRACTORS
    • BATH & KITCHEN PRO
    • BUSINESS MANAGEMENT
    • HIGH EFFICIENCY HOMES
    • TECHNOLOGY
    • WATER TREATMENT
    • PMC COLUMNS
      • Dave Yates: Contractor’s Corner
      • John Siegenthaler: Hydronics Workshop
      • Kenny Chapman: The Blue Collar Coach
      • Matt Michel: Service Plumbing Pros
      • Scott Secor: Heating Perceptions
  • ENGINEERS
    • CONTINUING EDUCATION
    • DECARBONIZATION | ELECTRIFICATION
    • FIRE PROTECTION
    • GEOTHERMAL | SOLAR THERMAL
    • PIPING | PLUMBING | PVF
    • PME COLUMNS
      • Christoph Lohr: Strategic Plumbing Insights
      • David Dexter: Plumbing Talking Points
      • James Dipping: Engineer Viewpoints
      • John Seigenthaler: Renewable Heating Design
      • Lowell Manalo: Plumbing Essentials
      • Misty Guard: Guard on Compliance
  • RADIANT & HYDRONICS
    • RADIANT COMFORT REPORT
    • THE GLITCH & THE FIX
  • INSIGHTS
    • CODES
    • GREEN PLUMBING & MECHANICAL
    • PROJECT PROFILES
    • COLUMNS
      • Codes Corner
      • Natalie Forster: Editorial Opinion
      • Guest Editorial
  • MEDIA
    • EBOOKS
    • PODCASTS
    • VIDEOS
    • WEBINARS
  • RESOURCES
    • INDUSTRY CALENDAR
    • DIRECTORIES
    • PM BOOKSTORE
    • CE CENTER
    • MARKET RESEARCH
    • CLASSIFIEDS
  • EMAGAZINE
    • EMAGAZINE
    • ARCHIVE ISSUES
    • CONTACT
    • ADVERTISE
    • PME EMAGAZINE ARCHIVES
  • SIGN UP!
Radiant & HydronicsThe Glitch & The Fix

The Glitch & The Fix: May 2025

Hydronic heating glitch solved: Why adding a circulator won't fix primary loop flow issue

Cut & cap

By John Siegenthaler, P.E.
Figure 1 is a sketch of the flow problems of the current plumbing system.
Drawing courtesy of John Siegenthaler
May 8, 2025
✕
Image in modal.

I was recently sent a sketch for the system very similar to that shown in figure 1.

FIGURE 1

Figure 1 is a sketch of the flow problems of the current plumbing system.
Drawing courtesy of John Siegenthaler

The Glitch:

When the system was operated the owner complained of flow problems. The heat emitters in any given zone were only marginally warmed when their associated zone circulator was operating. The owner questioned if another circulator should be installed in the area shown in figure 1. The rational being that the additional circulator would increase flow in the "primary loop." Do you think this will solve the problem? Are there any other potential issues with the layout? If so, how would you propose fixing them?

The Fix

The piping loop shown in black in figure 1 is NOT a primary loop. When a given zone circulator operates some of the flow returning from that zone may pass through the closely spaced tees where the gas boiler or wood-fired boiler connect. However, if the drawing is even close to scale, much of the flow returning from an active zone will just flow in reverse back to the circulator inlet for that zone. From a hydraulic standpoint that path is shorter than the one past the closely spaced tees where the boilers connect.

I suspect that the four zone circulator were arranged as shown in figure 1 in an attempt to get the same supply water temperature to each zone. This could work - but only if the total of all active zone flow rates is less than the flow around the piping loop, which in this system is going to be essentially impossible because there’s no circulator in that loop.

Although adding a high capacity circulator to the loop could conceivably solve the problem, it’s a "bandaid" solution to a fundamental design error. A better solution is to convert the black piping loop into a header system as shown in figure 2.

FIGURE 2

Figure 2 sketch of the fix – convert the black piping loop into a header system.
Drawing courtesy of John Siegenthaler

By simply cutting the loop to the right of the zone circulators, removing a short length of pipe, and capping the cut ends of the remaining piping, the loop has been covered to a supply and return header system. The zone circulators can now drive flow from the zone returns past the closely spaced tees that connect the two boilers to the system.

Other Problems: Never hang an expansion tank on its side as shown in figure 1. This puts high stress on the 1/2" nipple of the tank. If the diaphragm in the expansion tank ever fails, and the tank fills with water, there’s a good chance the stress could crack the connection.

The air separator was initially installed on the hot side of the gas-fired boiler. That’s OK from the standpoint that the hottest water with the lowest gas solubility may be coming from that boiler. However, if the wood-fired boiler is operating as the sole heat source the location of the air separator takes it out of the main flow path. It would be better located downstream of both boiler connections in the supply header as shown in figure 2.

Finally, a combination isolation / purging valve has been added to the outgoing pipe on the gas-fired boiler just upstream of where it connects to the closely-speed tees. That valve provides a way to isolation the boiler for service or replacement. It also expedites purging.

KEYWORDS: heating hydronics plumbing failures

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

John siegenthaler 200x200

John Siegenthaler, P.E., is a consulting engineer and principal of Appropriate Designs in Holland Patent, New York. In partnership with HeatSpring, he has developed several online courses that provide in-depth, design-level training in modern hydronics systems, air-to-water heat pumps and biomass boiler systems. Additional information and resources for hydronic system design are available on Siegenthaler’s website,  www.hydronicpros.com.

Recommended Content

JOIN TODAY
to unlock your recommendations.

Already have an account? Sign In

  • 2025 Next Gen ALL-STARS hero 1440

    2025 Next Gen All Stars: Top 20 Under 40 Plumbing Professionals

    This year’s group of NextGen All-Stars is full of young...
    Plumbing & Mechanical Contractor
    By: Kristen R. Bayles
  • Worker using the Milwaukee Tool SWITCH PACK drain cleaner

    Pipeline profits: Drain cleaning, pipe inspection create opportunities

    Drain cleaning and inspection services offer lucrative...
    Green Plumbing and Mechanical
    By: Nicole Krawcke
  • Uponor employee, Arturo Moreno

    The reinvestment in American manufacturing and training

    Plumbing & Mechanical Chief Editor Nicole Krawcke and...
    Plumbing News
    By: Nicole Krawcke and Natalie Forster
Manage My Account
  • eNewsletters
  • Online Registration
  • Subscription Customer Service
  • eMagazine
  • Manage My Preferences

More Videos

Popular Stories

Hot water pipes

Campus shutdown at Oakland University exposes hidden risks of aging hot-water infrastructure

Floor heating manifold cabinet with flowmeter and PEX pipe.

Elegance extended: How to use the homerun system of connecting heat emitters

Industrial pressure gauge on a tank.

From cutting edge to classic: How to modernize outdated pneumatic control systems

Poll

Will business be up or down in 2025?

Do you anticipate business in 2025 to be up or down in comparison to 2024?
View Results Poll Archive

Products

The Water Came To A Stop

The Water Came To A Stop

See More Products
eBook | 2025 Radiant & Hydronics All Stars

Related Articles

  • Selecting a Primary Loop Circulator--The Myths and the Facts

    See More
  • The Glitch

    The Glitch and Fix: Lose the loop

    See More
  • Why Use Hydronic Heating?

    See More

Related Products

See More Products
  • 51CHeeKvw4L._SX322_BO1,204,203,200_.jpg

    Hydronic Radiant Heating: A Practical Guide for the Nonengineer Installer

  • howcome.gif

    How Come? Hydronic heating questions we've been asking for 100 years (with straight answers!)

  • Residential_Hydronic_Heatin.gif

    Residential Hydronic Heating Systems Course

See More Products

Events

View AllSubmit An Event
  • October 22, 2025

    Optimizing Healthcare Piping: Why Schedule 80 CPVC is a Smarter, Safer Choice

    On Demand This webinar will examine the critical advantages of CPVC compared to metal and other plastics, including its resistance to harsh disinfection chemicals, ease of installation, and plenum-rated fire safety.
View AllSubmit An Event
×

Keep your content unclogged with our newsletters!

Stay in the know on the latest plumbing & piping industry trends.

JOIN TODAY!
  • RESOURCES
    • Advertise
    • Contact Us
    • Directories
    • Store
    • Want More
    • Supply House Times
  • SIGN UP TODAY
    • Create Account
    • eMagazine
    • eNewsletter
    • Customer Service
    • Manage Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2025. All Rights Reserved BNP Media.

Design, CMS, Hosting & Web Development :: ePublishing