• Sign In
  • Create Account
  • Sign Out
  • My Account
  • NEWS
  • PRODUCTS
  • CONTRACTORS
  • ENGINEERS
  • RADIANT & HYDRONICS
  • INSIGHTS
  • MEDIA
  • RESOURCES
  • EMAGAZINE
  • SIGN UP!
cart
facebook instagram twitter linkedin youtube
  • PRODUCTS
  • FEATURED PRODUCTS
  • CONTRACTORS
  • BATH & KITCHEN PRO
  • BUSINESS MANAGEMENT
  • HIGH EFFICIENCY HOMES
  • TECHNOLOGY
  • WATER TREATMENT
  • PMC COLUMNS
  • PMC COLUMNS
  • Dave Yates: Contractor’s Corner
  • John Siegenthaler: Hydronics Workshop
  • Kenny Chapman: The Blue Collar Coach
  • Matt Michel: Service Plumbing Pros
  • Scott Secor: Heating Perceptions
  • ENGINEERS
  • CONTINUING EDUCATION
  • DECARBONIZATION | ELECTRIFICATION
  • FIRE PROTECTION
  • GEOTHERMAL | SOLAR THERMAL
  • PIPING | PLUMBING | PVF
  • PME COLUMNS
  • PME COLUMNS
  • Christoph Lohr: Strategic Plumbing Insights
  • David Dexter: Plumbing Talking Points
  • James Dipping: Engineer Viewpoints
  • John Seigenthaler: Renewable Heating Design
  • Lowell Manalo: Plumbing Essentials
  • Misty Guard: Guard on Compliance
  • RADIANT & HYDRONICS
  • RADIANT COMFORT REPORT
  • THE GLITCH & THE FIX
  • INSIGHTS
  • CODES
  • GREEN PLUMBING & MECHANICAL
  • PROJECT PROFILES
  • COLUMNS
  • SPONSOR INSIGHTS
  • COLUMNS
  • Codes Corner
  • Natalie Forster: Editorial Opinion
  • Guest Editorial
  • MEDIA
  • EBOOKS
  • PODCASTS
  • VIDEOS
  • WEBINARS
  • RESOURCES
  • INDUSTRY CALENDAR
  • DIRECTORIES
  • PM BOOKSTORE
  • CE CENTER
  • MARKET RESEARCH
  • CLASSIFIEDS
  • EMAGAZINE
  • EMAGAZINE
  • ARCHIVE ISSUES
  • CONTACT
  • ADVERTISE
  • PME EMAGAZINE ARCHIVES
search
cart
facebook instagram twitter linkedin youtube
  • Sign In
  • Create Account
  • Sign Out
  • My Account
  • NEWS
  • PRODUCTS
    • FEATURED PRODUCTS
  • CONTRACTORS
    • BATH & KITCHEN PRO
    • BUSINESS MANAGEMENT
    • HIGH EFFICIENCY HOMES
    • TECHNOLOGY
    • WATER TREATMENT
    • PMC COLUMNS
      • Dave Yates: Contractor’s Corner
      • John Siegenthaler: Hydronics Workshop
      • Kenny Chapman: The Blue Collar Coach
      • Matt Michel: Service Plumbing Pros
      • Scott Secor: Heating Perceptions
  • ENGINEERS
    • CONTINUING EDUCATION
    • DECARBONIZATION | ELECTRIFICATION
    • FIRE PROTECTION
    • GEOTHERMAL | SOLAR THERMAL
    • PIPING | PLUMBING | PVF
    • PME COLUMNS
      • Christoph Lohr: Strategic Plumbing Insights
      • David Dexter: Plumbing Talking Points
      • James Dipping: Engineer Viewpoints
      • John Seigenthaler: Renewable Heating Design
      • Lowell Manalo: Plumbing Essentials
      • Misty Guard: Guard on Compliance
  • RADIANT & HYDRONICS
    • RADIANT COMFORT REPORT
    • THE GLITCH & THE FIX
  • INSIGHTS
    • CODES
    • GREEN PLUMBING & MECHANICAL
    • PROJECT PROFILES
    • COLUMNS
      • Codes Corner
      • Natalie Forster: Editorial Opinion
      • Guest Editorial
    • SPONSOR INSIGHTS
  • MEDIA
    • EBOOKS
    • PODCASTS
    • VIDEOS
    • WEBINARS
  • RESOURCES
    • INDUSTRY CALENDAR
    • DIRECTORIES
    • PM BOOKSTORE
    • CE CENTER
    • MARKET RESEARCH
    • CLASSIFIEDS
  • EMAGAZINE
    • EMAGAZINE
    • ARCHIVE ISSUES
    • CONTACT
    • ADVERTISE
    • PME EMAGAZINE ARCHIVES
  • SIGN UP!
Columns

One wimpy heater

By Dan Holohan
June 1, 2012
If you look at just one part of the steam system, you won’t be able to solve the problem.



So there’s this steam unit heater that won’t put out what it’s supposed to put out. It’s wimpy. The guy with the problem is telling me about it and he’s gesturing like he’s swatting bees. “The fan comes on and I get this hot blast, but then it goes cold,” he  said. “It’s like half the coil is hot and the other half is, well, meh.”

“What have you done so far?” I asked.

“I’ve been raising the pressure,” he  replied, swatting upward.

“Of course you have,” I said.

“But it’s still not working,” he  said. “Think I should raise it some more?”

In case you don’t know, the urge to crank up steam pressure is written into the genetic code of most American heating contractors. It goes back to the days of steam power. Ever notice how you get all drooly when in the presence of a steam locomotive? It’s all that raw power. Contractors have been sending me photos of steam locomotives for decades, even though steam power has nothing to do with steam heating. Equating the two is like going to an electrician for an electrocardiogram.

“How about if I raise it to 9 lb.,” he  said. “It’s at 7 now.”

“Tell me about the piping,” I said.

“It’s steel pipe,” he  said. “I don’t use copper on steam.”

“No, I mean where the pipes are,” I said. “Tell me about the supply and return piping to the heater. And what else is nearby?”

The physics of steam

That’s the thing about steam heating. It’s old and it can be scary, and it’s a system that reaches beyond the spot where the problem appears. If you look at just one part of that system, you probably won’t be able to solve the problem. You have to wander around and think in terms of basic physics. If you were the steam, what would you do? If you were air, could you get out?

Don’t let the physics scare you. Most of it is common sense and you already know everything you need to know. Most of it you learned in grade school.

For instance, water can be in three states - solid, liquid and gas. You know that already, right? Water will change temperature when you add or remove Btu. It takes 1 Btu to raise 1 lb. of water (that’s about a pint) 1° F. When 1 lb. of water reaches 212°, it’s still liquid. We call the heat that it takes to get to that point “sensible” heat because you can sense it with a thermometer.

To make that pound of water boil, you have to add 970 more Btu. We call that “latent” heat because the thermometer can’t see it. And that’s the stuff that heats the building.

Once you have steam, the only reason you need pressure is to overcome the friction loss the steam suffers as it travels though the piping on its way to the heater. An industry group called The Carbon Club set that standard in December 1899 when members got together at the Murray Hill Hotel in New York City and everyone agreed to use a pipe-sizing chart that would have the steam take a pressure drop of just 1 oz. for every 100 ft. it traveled through the pipe. This is how the Empire State Building manages to stay cozy warm with just 1 1/2-psi pressure on most days.

So crank down the pressure. No need for Casey Jones on this job.

You know most of this already, right? You also know that when water turns to steam, it expands quite a bit. The ratio is about 1,700:1 and that’s at 0 psi. Once it enters the pipe, the steam will shove air ahead of itself because air is heavier than steam and the two gases won’t mix. The steam plunges the air down the pipe. The air looks for a way out, and if it finds a vent, the heater will get hot and there will be peace in the valley. But if the air can’t get out, the steam can’t get in, and the client will be miserable.

“So about that supply and return piping,” I said. “What’s going on?”

“Well, there’s a control valve on the heater,” the contractor  said.

“What about on the return side? What’s there?”

“A float-and-thermostatic trap,” he  said.

“Where does the pipe go from there?”

“It goes to a condensate pump,” he  said. “And then back to the boiler.”

That’s a typical setup. You’ve probably seen it many times. But now I’d like you to think like steam and act like air and water. Before the steam arrives, the heater and all the piping leading to and from the heater contain air. Every steam system ever built starts out that way. It’s filled with air and the steam has to push that air out. This happens on every heating cycle. The steam has to shove that air out of its way before it can reach the heater.

“How does the piping run from the F&T trap to the inlet of the condensate pump?” I asked.

“It runs down to the floor, across the room and then it goes up into the receiver’s inlet,” he  replied.

I nod.

Can you see a problem with this?

When you drop a pipe to the floor and bring it up, it forms a water seal, right? In plumbing, you call that a P-trap. You know what a P-trap is supposed to do, don’t you? Its job is to stop gas in its tracks.

And what is air if not a gas?

“How is the air that’s inside the heater supposed to get to the vented condensate-pump’s receiver?” I asked.

“The steam pushes it through the trap and through the return pipe,” he  replied.

“What’s the job of a steam trap?” I asked.

“To trap steam,” he  said.

“So there’s no steam pressure beyond the trap, is there?”

“Uh, no,” he replied.

“And there’s a water seal in that return line. Air won’t vent through a water seal. And if the air can’t get out of the heater, the steam will just compress it inside the heater, giving you the problem you’re having now.”

At this point, he smacks himself in the forehead.

But wait, there’s more. He also has a control valve on the supply side of the heater. When that valve shuts, the steam inside the heater will condense, shrinking in volume by about 1,700 times. Since there’s no way for air to get back into the heater, you wind up with a vacuum inside the heater.

Have you ever held your finger over the top of a straw in a glass and then lifted it out of the glass? The water stays in the straw, right?

You learned that in grade school.      

“You need a vacuum breaker between the control valve and the heater,” I said. “And you also need a high-capacity air vent on the outlet side of the F&T trap.”

“I get it,” he  said. “That’s to give the air a way out.”

“Exactly, but that vent also serves another purpose,” I  explained. “When an F&T trap discharges, you get a bit of flash steam in the return. That flash steam will condense in the pipe on the outlet side of the trap and form a vacuum, and because you have a water seal in that line. The vacuum will slow the flow of water between the trap and the condensate pump and that’s not good. By placing the vent on the outlet side of the F&T trap rather than on its inlet side, the vent will do double duty. It will vent air, and also break any vacuum that forms when the trap closes.”

“This all seems so simple now,” he  said.

“That’s because you’re seeing it as a system now, and not just as a wimpy heater. Are there any other heaters nearby?”

“No. Why do you ask?”

“Because a failed trap in the open position can screw up a nearby heater that has a good trap. Bad traps create backpressure in the return line. Just keep thinking about systems.”

“So you think I should crank down the pressure?”

I just looked at him.

Links

  • Contact Plumbing & Mechanical
  • Follow PM on Twitter!
  • Like PM on Facebook!
KEYWORDS: hydronic heat steam heat

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

Holohan

Dan Holohan and his wife, Marianne, founded www.heatinghelp.com in 1997. You can reach Dan Holohan at dan@heatinghelp.com. He loves hearing from you!

Recommended Content

JOIN TODAY
to unlock your recommendations.

Already have an account? Sign In

  • Worker using the Milwaukee Tool SWITCH PACK drain cleaner

    Pipeline profits: Drain cleaning, pipe inspection create opportunities

    Drain cleaning and inspection services offer lucrative...
    Green Plumbing and Mechanical
    By: Nicole Krawcke
  • Uponor employee, Arturo Moreno

    The reinvestment in American manufacturing and training

    Plumbing & Mechanical Chief Editor Nicole Krawcke and...
    Plumbing News
    By: Nicole Krawcke and Natalie Forster
  • March 2024 Women in Plumbing hero image of woman engineer overlayed by circle of hexagon shapes with numbers from 1 to 10

    Celebrating 10 Influential Women in the Plumbing Industry

    Celebrating Women's History Month and Women in...
    Plumbing News
    By: Nicole Krawcke
Manage My Account
  • eNewsletters
  • Online Registration
  • Subscription Customer Service
  • eMagazine
  • Manage My Preferences

IPEX celebrates grand opening of new Florida distribution center

IPEX celebrates grand opening of new Florida distribution center

Bell & Gossett Illustrates Path to Net-zero at AHR Expo

Bell & Gossett Illustrates Path to Net-zero at AHR Expo

AI can boost efficiency and profitability for plumbing, HVAC contractors

AI can boost efficiency and profitability for plumbing, HVAC contractors

NIBCO Press Solutions

NIBCO Press Solutions

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to the Plumbing & Mechanical audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of Plumbing & Mechanical or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • J.J. Keller CMV vehicles on road
    Sponsored byJ. J. Keller & Associates, Inc.

    The dash cam game-changer for small business safety

Popular Stories

Integrate a heat pump with a boiler mounted on a brick wall.

How to integrate a heat pump with a boiler for dual temperature hydronic heating and cooling

Plumber using the DEWALT 20V MAX* Plastic Tubing Cutter to cut a white tube.

Making tough jobs easier: Most-used tools by plumbers in 2025

RCR Spring2025 Geothermal JHJ manifold-2

Geothermal and radiant: An energy-efficient powerhouse

Nominations for Plumbing & Mechanical's NextGen ALL-Stars are now open. Submit your nomination TODAY!

PM Aalberts August 14 Free Webinar: Precision Under Pressure: Optimizing System Performance Through Balancing and Air Removal

Events

November 13, 2024

Future Proofing MEP: Navigating the 2026 High Efficiency Water Heating Standards

Join our deep dive into DOE’s new standards so you can future-proof your MEP practice.

EARN: 0.1 ASPE CEU; 1 AIA LU/HSW; 0.1 IACET CEU*; 1 PDH

August 14, 2025

Precision Under Pressure: Optimizing System Performance Through Balancing and Air Removal

We’ll cover how proper air separation and hydronic balancing help maximize operational efficiency, reduce maintenance and minimize downtime.

View All Submit An Event

Poll

Will business be up or down in 2025?

Do you anticipate business in 2025 to be up or down in comparison to 2024?
View Results Poll Archive

Products

The Water Came To A Stop

The Water Came To A Stop

See More Products

2025 Bath & Kitchen Pro eBook

Related Articles

  • The house by Cedar Hill

    See More
  • Vertical heating

    See More
  • Old boiler room stuff

    See More
×

Keep your content unclogged with our newsletters!

Stay in the know on the latest plumbing & piping industry trends.

JOIN TODAY!
  • RESOURCES
    • Advertise
    • Contact Us
    • Directories
    • Store
    • Want More
    • Supply House Times
  • SIGN UP TODAY
    • Create Account
    • eMagazine
    • eNewsletter
    • Customer Service
    • Manage Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2025. All Rights Reserved BNP Media.

Design, CMS, Hosting & Web Development :: ePublishing

search
cart
facebook instagram twitter linkedin youtube
  • Sign In
  • Create Account
  • Sign Out
  • My Account
  • NEWS
  • PRODUCTS
    • FEATURED PRODUCTS
  • CONTRACTORS
    • BATH & KITCHEN PRO
    • BUSINESS MANAGEMENT
    • HIGH EFFICIENCY HOMES
    • TECHNOLOGY
    • WATER TREATMENT
    • PMC COLUMNS
      • Dave Yates: Contractor’s Corner
      • John Siegenthaler: Hydronics Workshop
      • Kenny Chapman: The Blue Collar Coach
      • Matt Michel: Service Plumbing Pros
      • Scott Secor: Heating Perceptions
  • ENGINEERS
    • CONTINUING EDUCATION
    • DECARBONIZATION | ELECTRIFICATION
    • FIRE PROTECTION
    • GEOTHERMAL | SOLAR THERMAL
    • PIPING | PLUMBING | PVF
    • PME COLUMNS
      • Christoph Lohr: Strategic Plumbing Insights
      • David Dexter: Plumbing Talking Points
      • James Dipping: Engineer Viewpoints
      • John Seigenthaler: Renewable Heating Design
      • Lowell Manalo: Plumbing Essentials
      • Misty Guard: Guard on Compliance
  • RADIANT & HYDRONICS
    • RADIANT COMFORT REPORT
    • THE GLITCH & THE FIX
  • INSIGHTS
    • CODES
    • GREEN PLUMBING & MECHANICAL
    • PROJECT PROFILES
    • COLUMNS
      • Codes Corner
      • Natalie Forster: Editorial Opinion
      • Guest Editorial
    • SPONSOR INSIGHTS
  • MEDIA
    • EBOOKS
    • PODCASTS
    • VIDEOS
    • WEBINARS
  • RESOURCES
    • INDUSTRY CALENDAR
    • DIRECTORIES
    • PM BOOKSTORE
    • CE CENTER
    • MARKET RESEARCH
    • CLASSIFIEDS
  • EMAGAZINE
    • EMAGAZINE
    • ARCHIVE ISSUES
    • CONTACT
    • ADVERTISE
    • PME EMAGAZINE ARCHIVES
  • SIGN UP!