• Sign In
  • Create Account
  • Sign Out
  • My Account
  • NEWS
  • PRODUCTS
  • CONTRACTORS
  • ENGINEERS
  • RADIANT & HYDRONICS
  • INSIGHTS
  • MEDIA
  • RESOURCES
  • EMAGAZINE
  • SIGN UP!
cart
facebook instagram twitter linkedin youtube
  • CONTRACTORS
  • BATH & KITCHEN PRO
  • BUSINESS MANAGEMENT
  • HIGH EFFICIENCY HOMES
  • TECHNOLOGY
  • WATER TREATMENT
  • PMC COLUMNS
  • PMC COLUMNS
  • Dave Yates: Contractor’s Corner
  • John Siegenthaler: Hydronics Workshop
  • Kenny Chapman: The Blue Collar Coach
  • Matt Michel: Service Plumbing Pros
  • Scott Secor: Heating Perceptions
  • ENGINEERS
  • CONTINUING EDUCATION
  • DECARBONIZATION | ELECTRIFICATION
  • FIRE PROTECTION
  • GEOTHERMAL | SOLAR THERMAL
  • PIPING | PLUMBING | PVF
  • PME COLUMNS
  • PME COLUMNS
  • Christoph Lohr: Strategic Plumbing Insights
  • David Dexter: Plumbing Talking Points
  • James Dipping: Engineer Viewpoints
  • John Seigenthaler: Renewable Heating Design
  • Lowell Manalo: Plumbing Essentials
  • Misty Guard: Guard on Compliance
  • RADIANT & HYDRONICS
  • RADIANT COMFORT REPORT
  • THE GLITCH & THE FIX
  • INSIGHTS
  • CODES
  • GREEN PLUMBING & MECHANICAL
  • PROJECT PROFILES
  • COLUMNS
  • SPONSOR INSIGHTS
  • COLUMNS
  • Codes Corner
  • Natalie Forster: Editorial Opinion
  • Guest Editorial
  • MEDIA
  • PODCASTS
  • VIDEOS
  • WEBINARS
  • RESOURCES
  • INDUSTRY CALENDAR
  • DIRECTORIES
  • EBOOKS
  • PM BOOKSTORE
  • CE CENTER
  • MARKET RESEARCH
  • CLASSIFIEDS
  • EMAGAZINE
  • EMAGAZINE
  • ARCHIVE ISSUES
  • CONTACT
  • ADVERTISE
  • PME EMAGAZINE ARCHIVES
search
cart
facebook instagram twitter linkedin youtube
  • Sign In
  • Create Account
  • Sign Out
  • My Account
  • NEWS
  • PRODUCTS
  • CONTRACTORS
    • BATH & KITCHEN PRO
    • BUSINESS MANAGEMENT
    • HIGH EFFICIENCY HOMES
    • TECHNOLOGY
    • WATER TREATMENT
    • PMC COLUMNS
      • Dave Yates: Contractor’s Corner
      • John Siegenthaler: Hydronics Workshop
      • Kenny Chapman: The Blue Collar Coach
      • Matt Michel: Service Plumbing Pros
      • Scott Secor: Heating Perceptions
  • ENGINEERS
    • CONTINUING EDUCATION
    • DECARBONIZATION | ELECTRIFICATION
    • FIRE PROTECTION
    • GEOTHERMAL | SOLAR THERMAL
    • PIPING | PLUMBING | PVF
    • PME COLUMNS
      • Christoph Lohr: Strategic Plumbing Insights
      • David Dexter: Plumbing Talking Points
      • James Dipping: Engineer Viewpoints
      • John Seigenthaler: Renewable Heating Design
      • Lowell Manalo: Plumbing Essentials
      • Misty Guard: Guard on Compliance
  • RADIANT & HYDRONICS
    • RADIANT COMFORT REPORT
    • THE GLITCH & THE FIX
  • INSIGHTS
    • CODES
    • GREEN PLUMBING & MECHANICAL
    • PROJECT PROFILES
    • COLUMNS
      • Codes Corner
      • Natalie Forster: Editorial Opinion
      • Guest Editorial
    • SPONSOR INSIGHTS
  • MEDIA
    • PODCASTS
    • VIDEOS
    • WEBINARS
  • RESOURCES
    • INDUSTRY CALENDAR
    • DIRECTORIES
    • EBOOKS
    • PM BOOKSTORE
    • CE CENTER
    • MARKET RESEARCH
    • CLASSIFIEDS
  • EMAGAZINE
    • EMAGAZINE
    • ARCHIVE ISSUES
    • CONTACT
    • ADVERTISE
    • PME EMAGAZINE ARCHIVES
  • SIGN UP!
Columns

Grounding
Carol Fey

By Carol Fey
February 1, 2005
Whether for safety or operation, knowing when to ground is essential.

Wha'd ya mean?" says Bubba the plumber-recently-turned-heating-tech. "How come you're tellin' me I gotta ground that boiler ignition? I know better - my power saw works just fine without a ground, and it's bigger!"

Bubba's right about one thing. His saw does work without a ground. It might be better if it didn't because it's not safe. Bubba doesn't care about that one way or another.

But the boiler ignition often doesn't work without a ground. Though, sometimes it might. What's going on here?

Inside out as it may sound, the smaller the electricity, the more we need a ground for operation. If the boiler ignition control runs on millivoltage, the issue isn't safety. It's all about getting the thing to work.

With the power saw that runs on 120V house wiring, it's the other way around. It doesn't need a ground to work. The ground is necessary to keep people safe and alive.

So we're talking about grounding for two different reasons. Let's look at the more familiar house wiring grounding first, and come back to controls.

House Wiring Ground

To understand the grounding of line voltage - or house wiring - let's review some very basic rules of electricity:
  • There must be a complete circuit. Electricity needs a way into the light bulb and a way back to where it came from - the power plant.

  • Electricity is just as happy to go into the earth (called earth ground) instead of back to the power plant.

  • Electricity is lazy and is always looking for the easiest way back to the power plant or earth ground.

  • If electricity can't find a proper path to the power plant or ground, you'll do just fine as a path to ground. (Ouch!)
When things are going right with house wiring, electricity comes in by way of the "hot" wire, goes through the load (light bulb, power tool, etc.) and goes back out through the "neutral." If electricity doesn't make it back through the neutral, I hope we've given it an alternate path through a "ground" wire. The ground wire goes literally to a stake in the earth, where electricity is safely absorbed into the ground. That's why it's called "earth ground."

Before the days of plastic pipe, a water pipe could be used as the path to ground instead of an actual stake. But plastic pipe and Teflon tape have made that undependable.

The ground wire keeps us humans safe because it's an easier path to ground than through us. If there's no ground, though, we're fair game. The reason that standing in a puddle of water or on a metal ladder is dangerous is that water and metal are great paths for electricity to get to ground, and we can help it along.

When Is A Ground Needed?

A ground is needed only when something goes wrong and there's stray electricity. Sometimes electricity can hop off its prescribed circuit. Let's say that inside a lamp the hot wire somehow touches metal. Going through the light bulb is a lot of work for electricity. If there's an opportunity, it's a lot easier to jump off the circuit and try another easier route. If it does and there's no grounding, when you touch the lamp - zap, you're the electrical conductor.

The same loose wire situation could happen inside a wall switch or receptacle. The loose wire touches the metal box, and the electricity is on the loose and looking for where to go next. If you make yourself available, you'll do just fine.

However, if the circuit is grounded, the electricity prefers the ground wire over you. Good choice!

Why Isn't Grounding Everywhere?

Before the 1960s, grounding house wiring wasn't required. So in buildings where the electricity was put in before then, you see wall receptacles with only two slots. It's possible but unlikely that those receptacles have since been grounded. It's easy to test to see if it is grounded, and we'll talk about that in a bit.

Most folks don't understand grounding, so the situation of the older two-slot receptacle and a modern three-prong appliance plug becomes simply a matter of making three prongs fit into two holes.

"No problem, man," Bubba crows. "I got two ways around that!"

Bubba's first choice is to grab his pliers and remove the third prong from the plug. "That's a no-brainer," he brags. "I don't know why everybody doesn't just do that."

If someone's watching, Bubba's second choice is to use an adapter. A lot of us innocently think an adapter is a safe solution. It certainly allows the three-prong plug to fit in the two-slot outlet. But it can be misleading. Even though the grounding prong is in the adapter, the appliance may not be grounded at all.

Here's where the adapter can fall painfully short.

  • If the receptacle isn't grounded, it's still not grounded when you use an adapter.

  • If the receptacle is grounded, the adapter still needs to be connected to the receptacle. Just plugging it in doesn't do the job.
The chances of both of these conditions happening are slim. So while the adapter lets you plug in the appliance, grounding is often an illusion. And certainly if you just keep an adapter in your toolbox or permanently on the plug, it's not giving you any safety.

There's an easy way to test the two-slot receptacle for grounding. Get a two-wire neon receptacle tester. They're cheap and available in hardware stores. With the power on, and the cover still on the receptacle, insert one probe in the short slot. Put the other on the screw in the middle of the receptacle, removing any paint first. If the tester glows, the receptacle is grounded.

If it doesn't glow, try putting one probe in the long slot and the other probe on the screw. If the tester glows, the receptacle is grounded, but hot and neutral polarity are reversed. More on that another time.

If the receptacle tests as grounded, then you can safely use the adapter. But you have to permanently attach it to the receptacle.

To attach the adapter to the receptacle, remove power from the outlet, remove the cover plate screw, plug in the adapter in the receptacle, put the screw through the ring on the adapter, and replace the screw into the cover plate. Turn the power back on.

Grounding Controls

Here's the only way to know whether or not you need to ground a control - read the installation instructions. If the manufacturer says to ground, then do it! It may be for your own safety, which you may or may not care about. But you do have a responsibility to make things safe for the end-user or the next technician.

However, grounding is essential for some controls to operate. In the case of boiler ignition, grounding is required to prove flame before the valve will fully open. Here's how it works. Since flame conducts electricity, the presence of a pilot flame can be used to complete a circuit. The brain in the electronic module is waiting for an electrical signal that there's flame before it'll fully open the valve. Since the signal is tiny little millivoltage, a ground from the module to the pilot burner (not to earth ground) is needed to keep the signal going to the module.

Most 24V controls don't need a ground. But what about line voltage controls? They do if they are a load - that means a user of electricity. A thermostat isn't grounded because it's a switch. But a circulator pump should be.

"Not so," says my friend Ed. "I've been putting in circulator pumps for years and I've never needed a ground. But just for the heck of it," he adds gracefully, "let's take a look."

Ed rustles around in his files and comes up with installation instructions. "Let's see here," he ponders. "It says ... Well, I'll be. It says it's supposed to be grounded."

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

Carol Fey is a degreed technical trainer, specializing in controls and electricity. She has published four books: Quick & Basic Electricity, Quick & Basic Hydronic Controls, Quick & Basic Troubleshooting, and Quick & Basic House Wiring. You can order books or get on the e-mail list for free technical information at www.carolfey.com. Or e-mail carol@carolfey.com.

Recommended Content

JOIN TODAY
to unlock your recommendations.

Already have an account? Sign In

  • Worker using the Milwaukee Tool SWITCH PACK drain cleaner

    Pipeline profits: Drain cleaning, pipe inspection create opportunities

    Drain cleaning and inspection services offer lucrative...
    Plumbing News
    By: Nicole Krawcke
  • Uponor employee, Arturo Moreno

    The reinvestment in American manufacturing and training

    Plumbing & Mechanical Chief Editor Nicole Krawcke and...
    Plumbing News
    By: Nicole Krawcke and Natalie Forster
  • March 2024 Women in Plumbing hero image of woman engineer overlayed by circle of hexagon shapes with numbers from 1 to 10

    Celebrating 10 Influential Women in the Plumbing Industry

    Celebrating Women's History Month and Women in...
    Plumbing News
    By: Nicole Krawcke
Subscribe For Free!
  • eNewsletters
  • Online Registration
  • Subscription Customer Service
  • eMagazine
  • Manage My Preferences

NIBCO Press Solutions

NIBCO Press Solutions

Bell & Gossett Illustrates Path to Net-zero at AHR Expo

Bell & Gossett Illustrates Path to Net-zero at AHR Expo

IPEX celebrates grand opening of new Florida distribution center

IPEX celebrates grand opening of new Florida distribution center

AI can boost efficiency and profitability for plumbing, HVAC contractors

AI can boost efficiency and profitability for plumbing, HVAC contractors

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to the Plumbing & Mechanical audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of Plumbing & Mechanical or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • J.J. Keller CMV vehicles on road
    Sponsored byJ. J. Keller & Associates, Inc.

    The dash cam game-changer for small business safety

Popular Stories

Figure 1 is a sketch of the flow problems of the current plumbing system.

Hydronic heating glitch solved: Why adding a circulator won't fix primary loop flow issue

The interior of a government building.

President Trump signs executive order promoting skilled trades and apprenticeships

Underfloor heating installation with drain sewer hole in bathroom close up on water floor heating.

Using hydronics to leverage time-of-use electrical rates

PM BEMIS June 25 Free Webinar: Optimizing Plumbing Solutions for Single-Family, Multi-Family & Public Spaces

Events

November 13, 2024

Future Proofing MEP: Navigating the 2026 High Efficiency Water Heating Standards

Join our deep dive into DOE’s new standards so you can future-proof your MEP practice.

EARN: 0.1 ASPE CEU; 1 AIA LU/HSW; 0.1 IACET CEU*; 1 PDH

View All Submit An Event

Poll

Will business be up or down in 2025?

Do you anticipate business in 2025 to be up or down in comparison to 2024?
View Results Poll Archive

Products

The Water Came To A Stop

The Water Came To A Stop

See More Products

Download the FREE Water Conservation, Quality & Safety eBook: Plumbing Trends Increasing Safe Water Availability

×

Keep your content unclogged with our newsletters!

Stay in the know on the latest plumbing & piping industry trends.

JOIN TODAY!
  • RESOURCES
    • Advertise
    • Contact Us
    • Directories
    • Store
    • Want More
    • Supply House Times
  • SIGN UP TODAY
    • Create Account
    • eMagazine
    • eNewsletter
    • Customer Service
    • Manage Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2025. All Rights Reserved BNP Media.

Design, CMS, Hosting & Web Development :: ePublishing

search
cart
facebook instagram twitter linkedin youtube
  • Sign In
  • Create Account
  • Sign Out
  • My Account
  • NEWS
  • PRODUCTS
  • CONTRACTORS
    • BATH & KITCHEN PRO
    • BUSINESS MANAGEMENT
    • HIGH EFFICIENCY HOMES
    • TECHNOLOGY
    • WATER TREATMENT
    • PMC COLUMNS
      • Dave Yates: Contractor’s Corner
      • John Siegenthaler: Hydronics Workshop
      • Kenny Chapman: The Blue Collar Coach
      • Matt Michel: Service Plumbing Pros
      • Scott Secor: Heating Perceptions
  • ENGINEERS
    • CONTINUING EDUCATION
    • DECARBONIZATION | ELECTRIFICATION
    • FIRE PROTECTION
    • GEOTHERMAL | SOLAR THERMAL
    • PIPING | PLUMBING | PVF
    • PME COLUMNS
      • Christoph Lohr: Strategic Plumbing Insights
      • David Dexter: Plumbing Talking Points
      • James Dipping: Engineer Viewpoints
      • John Seigenthaler: Renewable Heating Design
      • Lowell Manalo: Plumbing Essentials
      • Misty Guard: Guard on Compliance
  • RADIANT & HYDRONICS
    • RADIANT COMFORT REPORT
    • THE GLITCH & THE FIX
  • INSIGHTS
    • CODES
    • GREEN PLUMBING & MECHANICAL
    • PROJECT PROFILES
    • COLUMNS
      • Codes Corner
      • Natalie Forster: Editorial Opinion
      • Guest Editorial
    • SPONSOR INSIGHTS
  • MEDIA
    • PODCASTS
    • VIDEOS
    • WEBINARS
  • RESOURCES
    • INDUSTRY CALENDAR
    • DIRECTORIES
    • EBOOKS
    • PM BOOKSTORE
    • CE CENTER
    • MARKET RESEARCH
    • CLASSIFIEDS
  • EMAGAZINE
    • EMAGAZINE
    • ARCHIVE ISSUES
    • CONTACT
    • ADVERTISE
    • PME EMAGAZINE ARCHIVES
  • SIGN UP!