• Sign In
  • Create Account
  • Sign Out
  • My Account
  • NEWS
  • PRODUCTS
  • CONTRACTORS
  • ENGINEERS
  • RADIANT & HYDRONICS
  • INSIGHTS
  • MEDIA
  • RESOURCES
  • EMAGAZINE
  • SIGN UP!
cart
facebook instagram twitter linkedin youtube
  • CONTRACTORS
  • BATH & KITCHEN PRO
  • BUSINESS MANAGEMENT
  • HIGH EFFICIENCY HOMES
  • TECHNOLOGY
  • WATER TREATMENT
  • PMC COLUMNS
  • PMC COLUMNS
  • Dave Yates: Contractor’s Corner
  • John Siegenthaler: Hydronics Workshop
  • Kenny Chapman: The Blue Collar Coach
  • Matt Michel: Service Plumbing Pros
  • Scott Secor: Heating Perceptions
  • ENGINEERS
  • CONTINUING EDUCATION
  • DECARBONIZATION | ELECTRIFICATION
  • FIRE PROTECTION
  • GEOTHERMAL | SOLAR THERMAL
  • PIPING | PLUMBING | PVF
  • PME COLUMNS
  • PME COLUMNS
  • Christoph Lohr: Strategic Plumbing Insights
  • David Dexter: Plumbing Talking Points
  • James Dipping: Engineer Viewpoints
  • John Seigenthaler: Renewable Heating Design
  • Lowell Manalo: Plumbing Essentials
  • Misty Guard: Guard on Compliance
  • RADIANT & HYDRONICS
  • RADIANT COMFORT REPORT
  • THE GLITCH & THE FIX
  • INSIGHTS
  • CODES
  • GREEN PLUMBING & MECHANICAL
  • PROJECT PROFILES
  • COLUMNS
  • SPONSOR INSIGHTS
  • COLUMNS
  • Codes Corner
  • Natalie Forster: Editorial Opinion
  • Guest Editorial
  • MEDIA
  • PODCASTS
  • VIDEOS
  • WEBINARS
  • RESOURCES
  • INDUSTRY CALENDAR
  • DIRECTORIES
  • EBOOKS
  • PM BOOKSTORE
  • CE CENTER
  • MARKET RESEARCH
  • CLASSIFIEDS
  • EMAGAZINE
  • EMAGAZINE
  • ARCHIVE ISSUES
  • CONTACT
  • ADVERTISE
  • PME EMAGAZINE ARCHIVES
search
cart
facebook instagram twitter linkedin youtube
  • Sign In
  • Create Account
  • Sign Out
  • My Account
  • NEWS
  • PRODUCTS
  • CONTRACTORS
    • BATH & KITCHEN PRO
    • BUSINESS MANAGEMENT
    • HIGH EFFICIENCY HOMES
    • TECHNOLOGY
    • WATER TREATMENT
    • PMC COLUMNS
      • Dave Yates: Contractor’s Corner
      • John Siegenthaler: Hydronics Workshop
      • Kenny Chapman: The Blue Collar Coach
      • Matt Michel: Service Plumbing Pros
      • Scott Secor: Heating Perceptions
  • ENGINEERS
    • CONTINUING EDUCATION
    • DECARBONIZATION | ELECTRIFICATION
    • FIRE PROTECTION
    • GEOTHERMAL | SOLAR THERMAL
    • PIPING | PLUMBING | PVF
    • PME COLUMNS
      • Christoph Lohr: Strategic Plumbing Insights
      • David Dexter: Plumbing Talking Points
      • James Dipping: Engineer Viewpoints
      • John Seigenthaler: Renewable Heating Design
      • Lowell Manalo: Plumbing Essentials
      • Misty Guard: Guard on Compliance
  • RADIANT & HYDRONICS
    • RADIANT COMFORT REPORT
    • THE GLITCH & THE FIX
  • INSIGHTS
    • CODES
    • GREEN PLUMBING & MECHANICAL
    • PROJECT PROFILES
    • COLUMNS
      • Codes Corner
      • Natalie Forster: Editorial Opinion
      • Guest Editorial
    • SPONSOR INSIGHTS
  • MEDIA
    • PODCASTS
    • VIDEOS
    • WEBINARS
  • RESOURCES
    • INDUSTRY CALENDAR
    • DIRECTORIES
    • EBOOKS
    • PM BOOKSTORE
    • CE CENTER
    • MARKET RESEARCH
    • CLASSIFIEDS
  • EMAGAZINE
    • EMAGAZINE
    • ARCHIVE ISSUES
    • CONTACT
    • ADVERTISE
    • PME EMAGAZINE ARCHIVES
  • SIGN UP!
Columns

Dan Holohan: How to size a condensate pump

Some advice: Always try to see the system.

By Dan Holohan
Condensate Pump
November 27, 2020

Most manufacturers rate their condensate pumps in square feet EDR. You can easily convert whatever boiler rating you have to square feet EDR by using these conversion factors:

  • Multiply boiler horsepower (BHP) by 140 to get square feet EDR
  • Divide Btu/h by 240 to get square feet EDR; and
  • Multiply pounds of condensate per hour by 4 to get square feet EDR.

Once you have the rating in square feet EDR, you can select a condensate pump for that (or a slightly higher) rating from the manufacturer’s catalog. Most stock units will come with their pumps set to discharge at 20 psig pressure. That’s because the pump has to discharge at 5 psi higher than the pressure at which the boiler is operating. Low-pressure steam boilers operate up to 15 psi, so that’s why the condensate pump is capable of discharging at 20 psi. If you’re running the boiler at 2 psig, which is typical for heating, you’ll need to throttle the pump to 7 psi. If you don’t, the check valve at the pump’s discharge will rattle.

Manufacturers size the flow rate of the condensate pump to three times the system’s steaming rate to get the condensate back in the boiler as quickly as possible. That’s easy to figure because for every 1,000 square feet EDR, a boiler will lose 1/2 gpm of water to steam. That goes for all steam boilers, regardless of size or who makes them. 

Here’s an example: Let’s say you have a boiler rated for 8,000 square feet EDR (that’s about 60 BHP). The steaming rate of that boiler is 4 gpm. In other words, for each minute it’s firing, 4 gallons of water will turn to steam and head out into the system (1/2 gpm per 1,000 square feet EDR). 

We’d size a condensate pump for this system at three times the steaming rate (12 gpm) to make sure when the condensate returns from the system, it goes back into the boiler as quickly as possible. If we can help it, we don’t want this boiler to go off on low-water (or call on the automatic feeder). That’s also why manufacturers size the receiver to have a net storage capacity of about one minute’s worth of condensate. For this boiler, that would be 4 gallons. 

The receiver will have to hold more than 4 gallons of water, though. We don’t ever want to get to a point where the pump runs out of water and starts sucking wind. If we did that, the pump’s mechanical seal would fail and the pump would leak. So to be sure the pump’s suction is always flooded, condensate-pump manufacturers build in an allowance. They call this the gross storage capacity of the receiver. 

For that 8,000 square feet EDR system, you’d have a receiver with a gross capacity of about 9 gallons. The 4-gallon “net” storage capacity is the water between the pump-on and pump-off range of the float switch. In many cases, you can adjust the “net” storage capacity of the tank by adjusting the float lever’s swing. 

 

Don’t kill the boiler

If you’re looking at a rectangular condensate tank and you’re not sure what its “gross” storage capacity is, do this: Reduce all the dimensions to inches. Then multiply the length by the width by the height and divide your answer by 231. That will give you the total amount of water the receiver can hold (in gallons). The net storage capacity will be anywhere from one-third (in the larger units) to one-half (in the smaller units) of the gross storage capacity.

If you use a condensate pump as a transfer unit to return condensate from a remote part of the building back to a boiler-feed pump in the boiler room, you’ll have to take a few more things into consideration. 

For instance, let’s say you’re looking to replace a boiler in a building that has an old, buried wet return picking up the end of the steam main. You realize that those old, wet returns are leaking, and you know it’s a bad idea to replace the boiler without doing something about those leaking return lines. If they keep leaking, too much fresh water will come into the system, and that’s going to kill your new boiler. 

But what if it’s not practical or possible for the new return lines to run at floor level? Maybe there are too many doorways or hallways to cross over. Maybe that’s the reason they buried those return lines in the first place. 

Or, let’s say you plan to install a boiler-feed pump for that new low-water content steam boiler. By opening up the system (with the boiler-feed pump’s vented receiver), you’ll be changing wet returns into dry returns. That means you’ll need steam traps at the ends of the mains. This might be a good time to use a condensate transfer pump. You can get rid of those buried wet returns once and for all by picking up the end of the main through an F&T trap, which dumps the condensate into the new transfer pump. That will let you run a smaller overhead line back to the new boiler-feed pump. Your buried return problems are solved. 

But now that you’re pumping the condensate overhead, you’ll have to use more of that available pump pressure. How high up are you going with that line? 8 feet? 10 feet? You’ll have to allow about 1 psi of pump pressure for each 2 feet of vertical lift. If you’re going up 10 feet, you’ll need about 5 psig. Keep in mind, this isn’t like a closed hot-water heating system where the water is circulating around a closed, pressurized loop. There, we don’t have to worry about the lift because the weight of the water going down balances the weight of the water going up. But a condensate return system is open to the atmosphere. We have to lift that condensate up “over the hump.” Gravity will take care of the downhill part of the trip, sure, but we still have to get it up there. 

Allow 1 psi of pump pressure for each two feet of vertical lift. This is in addition to the pressure you need to overcome the resistance in the return line. How much you’ll need depends on the size and length of the line. 

For instance, let’s say you have to run 100 feet from your transfer pump back to your boiler-feed pump. I’m going to assume the discharge tapping on the transfer pump is 3/4-inch.  If you run that line back to the feed pump in 3/4-inch copper, the pressure drop will be a lot greater than it would be through, say, 1-inch copper. That’s because the 3/4-inch pipe is smaller than a 1-inch pipe. It can’t carry as much flow. 

The smaller pipe will slow the flow rate considerably, but this might not be important in this case. That’s because the condensate is returning to the boiler-feed pump’s receiver. The boiler won’t go off on low water; the feed pump will see to that. 

You don’t have to worry about boiler pressure here because you’re pumping back into the feed pump, not the boiler. The lift, pipe diameter and the length of run are the important considerations here. For instance, can you see how you’d have a problem with a “stock” pump if you had to lift condensate 40 feet and then move it horizontally a few hundred feet? That standard 20-psig discharge pressure probably wouldn’t be enough.

Of course, you’re not likely to run into this sort of situation on a steam heating job, but watch those commercial applications. 

One last word of caution: Never add a condensate pump without thinking about how it’s going to change the system. Are you turning wet returns into steam lines by adding that pump? Did you think about steam traps? You’ll need them now. Where are you going to put them? 

And if you’re using a transfer pump, are you going to discharge into an existing gravity return? If you are, have you given any thought to how this will affect those gravity returns? Will the condensate from the gravity-return portion of the system be able to flow when the pump is on? 

Give it some thought. Always try to see the system, not just the pump.

KEYWORDS: condensate pumps hydronic system design pump sizing

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

Holohan

Dan Holohan and his wife, Marianne, founded www.heatinghelp.com in 1997. You can reach Dan Holohan at dan@heatinghelp.com. He loves hearing from you!

Recommended Content

JOIN TODAY
to unlock your recommendations.

Already have an account? Sign In

  • Worker using the Milwaukee Tool SWITCH PACK drain cleaner

    Pipeline profits: Drain cleaning, pipe inspection create opportunities

    Drain cleaning and inspection services offer lucrative...
    Plumbing News
    By: Nicole Krawcke
  • Uponor employee, Arturo Moreno

    The reinvestment in American manufacturing and training

    Plumbing & Mechanical Chief Editor Nicole Krawcke and...
    Plumbing News
    By: Nicole Krawcke and Natalie Forster
  • March 2024 Women in Plumbing hero image of woman engineer overlayed by circle of hexagon shapes with numbers from 1 to 10

    Celebrating 10 Influential Women in the Plumbing Industry

    Celebrating Women's History Month and Women in...
    Plumbing News
    By: Nicole Krawcke
Subscribe For Free!
  • eNewsletters
  • Online Registration
  • Subscription Customer Service
  • eMagazine
  • Manage My Preferences

IPEX celebrates grand opening of new Florida distribution center

IPEX celebrates grand opening of new Florida distribution center

Bell & Gossett Illustrates Path to Net-zero at AHR Expo

Bell & Gossett Illustrates Path to Net-zero at AHR Expo

AI can boost efficiency and profitability for plumbing, HVAC contractors

AI can boost efficiency and profitability for plumbing, HVAC contractors

NIBCO Press Solutions

NIBCO Press Solutions

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to the Plumbing & Mechanical audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of Plumbing & Mechanical or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • J.J. Keller CMV vehicles on road
    Sponsored byJ. J. Keller & Associates, Inc.

    The dash cam game-changer for small business safety

Popular Stories

The interior of a government building.

President Trump signs executive order promoting skilled trades and apprenticeships

Figure 1 is a sketch of the flow problems of the current plumbing system.

Hydronic heating glitch solved: Why adding a circulator won't fix primary loop flow issue

Underfloor heating installation with drain sewer hole in bathroom close up on water floor heating.

Using hydronics to leverage time-of-use electrical rates

PM BEMIS June 25 Free Webinar: Optimizing Plumbing Solutions for Single-Family, Multi-Family & Public Spaces

Events

November 13, 2024

Future Proofing MEP: Navigating the 2026 High Efficiency Water Heating Standards

Join our deep dive into DOE’s new standards so you can future-proof your MEP practice.

EARN: 0.1 ASPE CEU; 1 AIA LU/HSW; 0.1 IACET CEU*; 1 PDH

View All Submit An Event

Poll

Will business be up or down in 2025?

Do you anticipate business in 2025 to be up or down in comparison to 2024?
View Results Poll Archive

Products

The Water Came To A Stop

The Water Came To A Stop

See More Products

Download the FREE Water Conservation, Quality & Safety eBook: Plumbing Trends Increasing Safe Water Availability

Related Articles

  • Holohan

    How to size a boiler-feed pump

    See More
  • Dan Holohan

    Dan Holohan: How to set a pressuretrol

    See More
  • Big or small, contractors do it all

    Dan Holohan: Does size matter?

    See More
×

Keep your content unclogged with our newsletters!

Stay in the know on the latest plumbing & piping industry trends.

JOIN TODAY!
  • RESOURCES
    • Advertise
    • Contact Us
    • Directories
    • Store
    • Want More
    • Supply House Times
  • SIGN UP TODAY
    • Create Account
    • eMagazine
    • eNewsletter
    • Customer Service
    • Manage Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2025. All Rights Reserved BNP Media.

Design, CMS, Hosting & Web Development :: ePublishing

search
cart
facebook instagram twitter linkedin youtube
  • Sign In
  • Create Account
  • Sign Out
  • My Account
  • NEWS
  • PRODUCTS
  • CONTRACTORS
    • BATH & KITCHEN PRO
    • BUSINESS MANAGEMENT
    • HIGH EFFICIENCY HOMES
    • TECHNOLOGY
    • WATER TREATMENT
    • PMC COLUMNS
      • Dave Yates: Contractor’s Corner
      • John Siegenthaler: Hydronics Workshop
      • Kenny Chapman: The Blue Collar Coach
      • Matt Michel: Service Plumbing Pros
      • Scott Secor: Heating Perceptions
  • ENGINEERS
    • CONTINUING EDUCATION
    • DECARBONIZATION | ELECTRIFICATION
    • FIRE PROTECTION
    • GEOTHERMAL | SOLAR THERMAL
    • PIPING | PLUMBING | PVF
    • PME COLUMNS
      • Christoph Lohr: Strategic Plumbing Insights
      • David Dexter: Plumbing Talking Points
      • James Dipping: Engineer Viewpoints
      • John Seigenthaler: Renewable Heating Design
      • Lowell Manalo: Plumbing Essentials
      • Misty Guard: Guard on Compliance
  • RADIANT & HYDRONICS
    • RADIANT COMFORT REPORT
    • THE GLITCH & THE FIX
  • INSIGHTS
    • CODES
    • GREEN PLUMBING & MECHANICAL
    • PROJECT PROFILES
    • COLUMNS
      • Codes Corner
      • Natalie Forster: Editorial Opinion
      • Guest Editorial
    • SPONSOR INSIGHTS
  • MEDIA
    • PODCASTS
    • VIDEOS
    • WEBINARS
  • RESOURCES
    • INDUSTRY CALENDAR
    • DIRECTORIES
    • EBOOKS
    • PM BOOKSTORE
    • CE CENTER
    • MARKET RESEARCH
    • CLASSIFIEDS
  • EMAGAZINE
    • EMAGAZINE
    • ARCHIVE ISSUES
    • CONTACT
    • ADVERTISE
    • PME EMAGAZINE ARCHIVES
  • SIGN UP!