search
cart
facebook instagram twitter linkedin youtube
  • Sign In
  • Create Account
  • Sign Out
  • My Account
  • NEWS
  • PRODUCTS
    • FEATURED PRODUCTS
  • CONTRACTORS
    • BATH & KITCHEN PRO
    • BUSINESS MANAGEMENT
    • HIGH EFFICIENCY HOMES
    • TECHNOLOGY
    • WATER TREATMENT
    • PMC COLUMNS
      • Dave Yates: Contractor’s Corner
      • John Siegenthaler: Hydronics Workshop
      • Kenny Chapman: The Blue Collar Coach
      • Matt Michel: Service Plumbing Pros
      • Scott Secor: Heating Perceptions
  • ENGINEERS
    • CONTINUING EDUCATION
    • DECARBONIZATION | ELECTRIFICATION
    • FIRE PROTECTION
    • GEOTHERMAL | SOLAR THERMAL
    • PIPING | PLUMBING | PVF
    • PME COLUMNS
      • Christoph Lohr: Strategic Plumbing Insights
      • David Dexter: Plumbing Talking Points
      • James Dipping: Engineer Viewpoints
      • John Seigenthaler: Renewable Heating Design
      • Lowell Manalo: Plumbing Essentials
      • Misty Guard: Guard on Compliance
  • RADIANT & HYDRONICS
    • RADIANT COMFORT REPORT
    • THE GLITCH & THE FIX
  • INSIGHTS
    • CODES
    • GREEN PLUMBING & MECHANICAL
    • PROJECT PROFILES
    • COLUMNS
      • Codes Corner
      • Natalie Forster: Editorial Opinion
      • Guest Editorial
  • MEDIA
    • EBOOKS
    • PODCASTS
    • VIDEOS
    • WEBINARS
  • RESOURCES
    • INDUSTRY CALENDAR
    • DIRECTORIES
    • PM BOOKSTORE
    • CE CENTER
    • MARKET RESEARCH
    • CLASSIFIEDS
  • EMAGAZINE
    • EMAGAZINE
    • ARCHIVE ISSUES
    • CONTACT
    • ADVERTISE
    • PME EMAGAZINE ARCHIVES
  • SIGN UP!
Plumbing NewsPlumbing, HVAC and Fire Protection CodesCodes Corner

Legionella prevention and codes

Methods of disinfection in the model codes.

By Conrad Jahrling
Legionella prevention and codes

It has taken years to be mentioned in the model codes, but there finally appears to be some movement to address the issue.

February 10, 2020

It’s a sign that a topic is going mainstream when it becomes cited in the model codes. Unfortunately, Legionella prevention has broken that barrier during this cycle due to increased hospitalizations and deaths. It has taken years to be mentioned in the model codes, but there finally appears to be some movement to address the issue.

Since the early days, the Uniform Plumbing Code (UPC) and International Plumbing Code (IPC) have required the disinfection of new potable water systems, or as required by the authority having jurisdiction (AHJ). If the AHJ does not have a method prescribed, the method is to:

  1. Flush the entire system with potable water.
  2. Fill the system with chlorinated water, typically as chlorine gas or sodium hypochlorite (bleach). If the chlorine concentration is greater than 50 ppm, let the system stand for 24 hours. Else if the concentration is greater than 200 ppm, wait 3 hours.
  3. Flush the entire system again with potable water until the residual chlorine is removed.
  4. Perform a bacteriological evaluation and repeat the disinfection until satisfied.

In addition, the IPC alternatively allows use of the procedures found in AWWA C651, Disinfecting Water Mains, or AWWA C652, Disinfection of Water Storage Facilities, again using chlorination.

While not specified as a method of disinfection in the model codes, elevated water temperature is also widely used. ASSE 1084, Performance Requirements for Water Heaters with Temperature Limiting Capacity, and ASSE 1085, Performance Requirements for Water Heaters for Emergency Equipment, are both incorporated into the 2021 IPC and have tentatively been incorporated into the 2021 UPC. Water heaters conforming to these standards give another way to combat Legionella. By designing systems with these devices at points-of-use, there is less opportunity for dormant, warm water at the ideal growth temperature range to be present within the hot water distribution system. These water heaters can precisely control the output temperature so tightly that an ASSE 1070 (Water Temperature Limiting Device) or ASSE 1071 (Temperature Actuated Mixing Valve for Plumbed Emergency Equipment) is not required downstream. 

Alternatively, a water heater conforming to ASSE 1082, Performance Requirements for Water Heaters with Integral Temperature Control Devices for Hot Water Distribution Systems, can be installed at the system inlet and can maintain an elevated temperature to the same tolerances as an ASSE 1017 (Temperature Actuated Mixing Valve for Hot Water Distribution Systems). Note that an ASSE 1069 (Automatic Temperature Control Mixing Valve) is used for gang showers and an ASSE 1016 (Automatic Compensating Valve for Individual Showers and Tub/Shower Combinations) is used for individual showers and tub/shower combinations.

One of the other public comment proposals for the UPC aims to add Appendix N (Impact of Water Temperature on the Potential for Scalding and Legionella Growth), which gives guidance of various water temperature ranges and its relationship to both scalding and Legionella growth. This will be useful in designing hot water distribution systems because one can quickly understand and reference that it is inappropriate to set the maximum system temperature at the water heater to 120° F (49° C). The resulting downstream heat losses could potentially allow for ideal growth of Legionella at 95° – 115° F (35° – 46° C). Instead, design your system to have a time and temperature dwell that disinfects incoming and recirculation loop water, and minimize stagnant water by eliminating or reducing the number of dead legs. 

Finally, the proposal incorporates ANSI/ASHRAE Standard 188, Legionellosis: Risk Management for Building Water Systems, as an acceptable reference in Table 1701.2. The standard lays out the risk management requirements for designing, building, repairing or expanding water systems in order to minimize the effects of Legionella. This will be the first time ASHRAE 188 is referenced in a model code and it symbolizes a noteworthy step.

As Legionella prevention gets more attention and becomes more mainstream, ASSE International will be looking closely at the next code cycle for the year 2024 while continuing to develop product and professional qualifications stand-ards to help installers, designers and the public.

KEYWORDS: codes and standards Legionella plumbers and pipefitters

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

Conrad Jahrling is the staff engineering supervisor at ASSE International, helping plumbing professionals develop water safety standards for backflow, scald prevention and water treatment.

Recommended Content

JOIN TODAY
to unlock your recommendations.

Already have an account? Sign In

  • 2025 Next Gen ALL-STARS hero 1440

    2025 Next Gen All Stars: Top 20 Under 40 Plumbing Professionals

    This year’s group of NextGen All-Stars is full of young...
    Plumbing & Mechanical Engineer
    By: Kristen R. Bayles
  • Worker using the Milwaukee Tool SWITCH PACK drain cleaner

    Pipeline profits: Drain cleaning, pipe inspection create opportunities

    Drain cleaning and inspection services offer lucrative...
    Green Plumbing and Mechanical
    By: Nicole Krawcke
  • Uponor employee, Arturo Moreno

    The reinvestment in American manufacturing and training

    Plumbing & Mechanical Chief Editor Nicole Krawcke and...
    Plumbing News
    By: Nicole Krawcke and Natalie Forster
Manage My Account
  • eNewsletters
  • Online Registration
  • Subscription Customer Service
  • eMagazine
  • Manage My Preferences

More Videos

Popular Stories

Hot water pipes

Campus shutdown at Oakland University exposes hidden risks of aging hot-water infrastructure

Floor heating manifold cabinet with flowmeter and PEX pipe.

Elegance extended: How to use the homerun system of connecting heat emitters

Industrial pressure gauge on a tank.

From cutting edge to classic: How to modernize outdated pneumatic control systems

Poll

Will business be up or down in 2025?

Do you anticipate business in 2025 to be up or down in comparison to 2024?
View Results Poll Archive

Products

The Water Came To A Stop

The Water Came To A Stop

See More Products
eBook | 2025 Radiant & Hydronics All Stars

Related Articles

  • Legionella Prevention

    Legionella prevention, labor shortage top commercial plumbing trends

    See More
  • Microscopic magnification of Legionella pneumophila, a Gram-negative bacillus that causes pneumonia.

    Legionella cases are leveling off, but experts say we must ramp up prevention

    See More
  • Latest Headlines

    CDC to address COVID-19 impact on Legionnaires’ Disease, present new prevention tools at Legionella Conference

    See More

Related Products

See More Products
  • The ACCA Job Safety (1).jpg

    The ACCA On-The-Job Safety Handbook (Pack of 5)

  • Significant Changes to the International Building Code 2015 Edition

  • plumbing code.jpg

    2018 International Plumbing Code®

See More Products
×

Keep your content unclogged with our newsletters!

Stay in the know on the latest plumbing & piping industry trends.

JOIN TODAY!
  • RESOURCES
    • Advertise
    • Contact Us
    • Directories
    • Store
    • Want More
    • Supply House Times
  • SIGN UP TODAY
    • Create Account
    • eMagazine
    • eNewsletter
    • Customer Service
    • Manage Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2025. All Rights Reserved BNP Media.

Design, CMS, Hosting & Web Development :: ePublishing