This website requires certain cookies to work and uses other cookies to help you have the best experience. By visiting this website, certain cookies have already been set, which you may delete and block. By closing this message or continuing to use our site, you agree to the use of cookies. Visit our updated privacy and cookie policy to learn more.
This Website Uses Cookies
By closing this message or continuing to use our site, you agree to our cookie policy. Learn More
This website requires certain cookies to work and uses other cookies to help you have the best experience. By visiting this website, certain cookies have already been set, which you may delete and block. By closing this message or continuing to use our site, you agree to the use of cookies. Visit our updated privacy and cookie policy to learn more.
search
cart
facebook twitter linkedin youtube
  • Sign In
  • Create Account
  • Sign Out
  • My Account
  • Home
  • Products
  • News
  • Glitch & Fix
  • Hydronics
  • Radiant
    • Radiant Comfort Report
  • Blogs/Columns
    • R&H On The Road
    • John Siegenthaler
    • Dan Holohan
    • Ray Wohlfarth
    • Mark Eatherton: Radiant Know-How
  • Buyers Guide
  • Resources
    • Radiant Comfort Report Digital
    • Rep Locator
    • Industry Calendar
    • Store
    • Market Research
    • eNewsletters
  • Plumbing & Mechanical
Home » Radiant Floor Heat And Mod/Con Boilers
The Glitch & The FixRadiant & Hydronics

Radiant Floor Heat And Mod/Con Boilers

June 18, 2010
John Siegenthaler, P.E.
Reprints
No Comments


The Glitch

Overview: A project requires both medium- and low-temperature radiant floor panels. The installer proposes the following system design. Since the mod/con boiler already has an internal outdoor reset controller, he decides to use a standard 1-inch tempering valve to lower the water supply temperature to the lower temperature zones. He also decides that since the boiler supply and return connections are 1 inch, he can pipe the entire system with 1-inch tubing.

Exercise: Can you spot at least six design or installation details that are going to create problems?

The Fix

The header piping in the original design is the same size (1-inch) as the piping to individual zone circulators. This will likely create a high pressure drop when all zone circulators are operating. The pipe size of the distribution headers in the fix drawing has been increased to minimize head loss and, thus, minimize hydraulic interference between zones.

The boiler circulator needs to be hydraulically separated from the circulators in the distribution system. This has been corrected using the closely spaced tees.

The 1-inch tempering valve with Cv = 3.0 has been replaced with a properly sized three-way rotary mixing valve with much higher Cv (Cv = 10) and hence lower pressure drop. Although a motorized actuator is shown on the mixing valve, it may not be required.

A manually set (nonthermostatic/nonmotorized) three-way valve can provide proportional reset control to the lower temperature zones when the hot water supplied to the valve is reset by the boiler. The motorized actuator is recommended in situations where the lower temperature zones will have frequent setback or temperature adjustment. A check valve is installed in the hot water pipe to the three-way valve to prevent flow reversal when other zones are operating.

The remaining glitches and their corrections are as follows:
  • A microbubble air separator has been added such that flow from the boiler passes through it during both space heating and DHW operating modes.  

  • In the original drawing, the purging valves on the return side of the zone circuits were installed backwards.  

  • In the original drawing, all zone circulators are shown with very little distance between their inlet port and the header. This distance should be a minimum of 12 pipe diameters to reduce the level of turbulence entering the circulator.  

  • The DHW circulator in the original drawing lacks a check valve. Without it, there will be some reverse flow through the coil of the indirect water heater when the space-heating portion of the system is operating.  

  • Finally, the point of no pressure change in the original system is incorrectly located on the discharge side of the circulators.


Links

  • The Glitch & The Fix - June 2010

pm-subscribe

Recent Articles by John Siegenthaler, P.E.

John Siegenthaler: New in the neighborhood

The Glitch and Fix: Keep the cost down

Single coil solution

John Siegenthaler: Low temperature leverage

John Siegenthaler: Expansion etiquette

Siegenthaler

John Siegenthaler, P.E., is a consulting engineer and principal of Appropriate Designs in Holland Patent, N.Y. His latest textbook “Heating With Renewable Energy,” will be released in January 2016 from Cengage Publishing. It shows how to use modern hydronics technology to create systems supplied by solar thermal, heat pump and biomass heat sources. Additional information is available at www.hydronicpros.com.

Related Articles

Geothermal Heat Pump, Mod/Con Boiler For Radiant Floor Heating

Simplified piping for heat pump, mod/con boiler

Radiant floor heating with pellet boiler

Radiant floor panels supplied by pellet-fired boiler

Related Products

Lessons Learned in a Boiler Room: A common sense approach to servicing and installing commercial boilers

Hydronic Radiant Heating: A Practical Guide for the Nonengineer Installer

Modern Hydronic Heating: For Residential and Light Commercial Buildings, 3rd Ed.

Greening Steam: How to Bring 19th-Century Heating Systems into the 21st Century (and save lots of green!)

Related Events

Coffee with Caleffi and John Siegenthaler: Air Source and Water Source Heat Pump Systems.

You must login or register in order to post a comment.

Report Abusive Comment

RCR logo

RCR Buyers Guide

Plumbing and Mechanical

Plumbing & Mechanical December 2019

2019 December

Check out the December 2019 edition of Plumbing & Mechanical: 2020 B.I.G. Book, John Siegenthaler on geothermal water-to-water heat pump system design and installation, maximizing efficiency on small-diameter piping projects and much more!
View More Create Account
  • Resources
    • Reprints
    • List Rental
    • Contact Us
    • AEC Store
    • Blogs
    • Radiant & Hydronics
    • Industry Links
    • Market Research
    • Custom Content & Marketing Services
    • Privacy Policy
  • Want More
    • Connect
    • Survey And Sample
  • Plumbing Group
    • PM Engineer
    • Supply House Times
  • Advertise
    • Advertise
    • Plan for 2020!

Copyright ©2019. All Rights Reserved BNP Media.

Design, CMS, Hosting & Web Development :: ePublishing