search
cart
facebook instagram twitter linkedin youtube
  • Sign In
  • Create Account
  • Sign Out
  • My Account
  • NEWS
  • PRODUCTS
    • FEATURED PRODUCTS
  • CONTRACTORS
    • BATH & KITCHEN PRO
    • BUSINESS MANAGEMENT
    • HIGH EFFICIENCY HOMES
    • TECHNOLOGY
    • WATER TREATMENT
    • PMC COLUMNS
      • Dave Yates: Contractor’s Corner
      • John Siegenthaler: Hydronics Workshop
      • Kenny Chapman: The Blue Collar Coach
      • Matt Michel: Service Plumbing Pros
      • Scott Secor: Heating Perceptions
  • ENGINEERS
    • CONTINUING EDUCATION
    • DECARBONIZATION | ELECTRIFICATION
    • FIRE PROTECTION
    • GEOTHERMAL | SOLAR THERMAL
    • PIPING | PLUMBING | PVF
    • PME COLUMNS
      • Christoph Lohr: Strategic Plumbing Insights
      • David Dexter: Plumbing Talking Points
      • James Dipping: Engineer Viewpoints
      • John Seigenthaler: Renewable Heating Design
      • Lowell Manalo: Plumbing Essentials
      • Misty Guard: Guard on Compliance
  • RADIANT & HYDRONICS
    • RADIANT COMFORT REPORT
    • THE GLITCH & THE FIX
  • INSIGHTS
    • CODES
    • GREEN PLUMBING & MECHANICAL
    • PROJECT PROFILES
    • COLUMNS
      • Codes Corner
      • Natalie Forster: Editorial Opinion
      • Guest Editorial
  • MEDIA
    • EBOOKS
    • PODCASTS
    • VIDEOS
    • WEBINARS
  • RESOURCES
    • INDUSTRY CALENDAR
    • DIRECTORIES
    • PM BOOKSTORE
    • CE CENTER
    • MARKET RESEARCH
    • CLASSIFIEDS
  • EMAGAZINE
    • EMAGAZINE
    • ARCHIVE ISSUES
    • CONTACT
    • ADVERTISE
    • PME EMAGAZINE ARCHIVES
  • SIGN UP!
Columns

Using a flame safeguard control

By Ray Wohlfarth
March 1, 2012
Avoid potential boiler explosions with this safety device.

Photo credit: Ray Wohlfarth


As I accompanied my friend from the local utility company into the boiler room, I noticed the covers were off all the electrical boxes and wires were hanging out of them. That is never a good sign. The purpose of my visit was to offer some suggestions to help the client lower its fuel costs, as it was  having a difficult time paying its gas bill. Our meeting included the director of maintenance and his boiler maintenance staff.

As we were talking with the maintenance personnel in the boiler room, the lead boiler tech said he needed to start the boiler. I watched as he walked to one of the large boilers and opened the door to the base of the boiler. He took a broom, lit the bristles on fire and shoved the lit broom inside.

His next task froze me. He opened a 2 1/2-in. manual gas valve and the burner started with a soft “Whoom.” Flames were visible from the opening of the boiler. He pulled the broom out and stomped on it to extinguish it.

Table 1.

I gasped loudly and the maintenance man laughed. “Why do you do that?” I asked.

“Aw, the flame safeguard is defective. Do you know how much those things are?” he answered.

“So you bypassed it?” I stammered.

“Yep, been like that for months now. Whenever we need heat, we just light the broom and off we go. You gotta be careful sometimes as that flame will singe your hair,” he said.

I do not know whether I was more concerned with how they “lit” their boiler or that they thought it was OK to do.

The maintenance man is correct. A flame safeguard is much more expensive than a simple thermocouple. Some maintenance people will ask why the industry has gone away from thermocouples. The main reason is response time. The response time for a thermocouple is between one and three minutes. A flame safeguard will respond within four seconds.

It may not seem like a big deal but consider this. If the flame goes out on a 1 million Btuh boiler with a thermocouple and the thermocouple response time is two minutes, the boiler will have about 16 cubic ft. of gas.  Mixed with the combustion air, it would equal about 240 cubic ft. of an explosive mixture.

Contrast that with a boiler with a modern flame safeguard with a four-second response time. It would allow slightly more than 1 cubic ft. of gas and the explosive mixture of air and gas would be about 16 cubic ft. - about 94% less.

Table 2.

How it works

During my seminars, I am often asked how a flame safeguard operates. A flame safeguard is a sophisticated control that monitors fuel-burning equipment to assure safe operation. On a call for heat, the flame safeguard will start the burner fan. The blower operation is verified with a sensing device, usually a pressure switch.

If the burner is a modulating one, the burner air intake damper will open. This is called a “pre-purge.” The fan will operate for anywhere from 30 seconds to several minutes. This is to “purge” the boiler combustion chamber of any unburnt fuel. The purge will be enough to provide four full air changes in the combustion chamber.

After the pre-purge, the pilot will light. The flame safeguard will check the pilot flame to make sure that it is safe and stable. If the burner is a modulating one, it will drive to a low fire position.

At that point, the main gas valve will open. The flame safeguard will continually monitor the flame until the call for heat has ended. Some older burners used a “post-purge” to void the combustion chamber of any unburnt fuel after the call for heat. This is wasteful as it will take heat from the boiler and exhaust it up the stack.

Another consideration with flame safeguards are the flame-sensing types. The four common flame-sensing devices are: flame rectification (more commonly known as a flame rod); photo cell; ultraviolet; and infrared.

Flame rectification is the most common sensing device. It uses a theory that a flame will actually conduct electricity. I wonder how many singed eyebrows there were when they tried to test that theory! A small electrical charge will be sent to the flame rod. If a flame is present, the current will travel through the flame to the ground. If the ground is sensed, the main gas valve will open.

The photo cell, common for fuel-oil burners, looks for the visible light of a flame. When light is present, the sensor will emit electrons and tell the flame safeguard that a flame is present.

Infrared flame sensors can be used on either gas or fuel-oil burners. It senses the infrared radiation that is present in a flame. However, it can sometimes be fooled by hot refractory inside a boiler.

Ultraviolet flame sensing tests for the ultraviolet waves that are present inside a flame. The UV sensor will not respond to any visible light. It can be fooled by hot refractory, spark ignition, gas laser, sun lamps, germicidal lights and a bright flashlight.

The best way to check the operation of a flame safeguard is with a meter. Tables 1 and 2 will show you the suggested readings for different flame safeguards.

Links

  • Contact Plumbing & Mechanical
  • Follow PM on Twitter!
KEYWORDS: commercial boilers hydronic heat

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

Ray Wohlfarth is the author of “Lessons Learned in a Boiler Room: A common-sense approach to servicing and installing commercial boilers.” In his spare time, he is president of Fire & Ice in Pittsburgh, Pa. Ray writes a monthly newsletter on commercial boilers. He can be reached at 412/343-4110.

Recommended Content

JOIN TODAY
to unlock your recommendations.

Already have an account? Sign In

  • 2025 Next Gen ALL-STARS hero 1440

    2025 Next Gen All Stars: Top 20 Under 40 Plumbing Professionals

    This year’s group of NextGen All-Stars is full of young...
    Plumbing & Mechanical Contractor
    By: Kristen R. Bayles
  • Worker using the Milwaukee Tool SWITCH PACK drain cleaner

    Pipeline profits: Drain cleaning, pipe inspection create opportunities

    Drain cleaning and inspection services offer lucrative...
    Green Plumbing and Mechanical
    By: Nicole Krawcke
  • Uponor employee, Arturo Moreno

    The reinvestment in American manufacturing and training

    Plumbing & Mechanical Chief Editor Nicole Krawcke and...
    Plumbing News
    By: Nicole Krawcke and Natalie Forster
Manage My Account
  • eNewsletters
  • Online Registration
  • Subscription Customer Service
  • eMagazine
  • Manage My Preferences

More Videos

Popular Stories

Hot water pipes

Campus shutdown at Oakland University exposes hidden risks of aging hot-water infrastructure

Floor heating manifold cabinet with flowmeter and PEX pipe.

Elegance extended: How to use the homerun system of connecting heat emitters

Industrial pressure gauge on a tank.

From cutting edge to classic: How to modernize outdated pneumatic control systems

Poll

Will business be up or down in 2025?

Do you anticipate business in 2025 to be up or down in comparison to 2024?
View Results Poll Archive

Products

The Water Came To A Stop

The Water Came To A Stop

See More Products
eBook | 2025 Radiant & Hydronics All Stars

Related Articles

  • Performing a boiler combustion analysis

    See More
  • Should you re-use existing flue and chimney when replacing a boiler?

    See More
  • Ray Wohlfarth: A dangerous situation

    See More

Related Products

See More Products
  • Lessons Learned in a Boiler Room: A common sense approach to servicing and installing commercial boilers

  • 51CHeeKvw4L._SX322_BO1,204,203,200_.jpg

    Hydronic Radiant Heating: A Practical Guide for the Nonengineer Installer

  • Optimizing Social Media from a B2B Perspective

See More Products
×

Keep your content unclogged with our newsletters!

Stay in the know on the latest plumbing & piping industry trends.

JOIN TODAY!
  • RESOURCES
    • Advertise
    • Contact Us
    • Directories
    • Store
    • Want More
    • Supply House Times
  • SIGN UP TODAY
    • Create Account
    • eMagazine
    • eNewsletter
    • Customer Service
    • Manage Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2025. All Rights Reserved BNP Media.

Design, CMS, Hosting & Web Development :: ePublishing