• Sign In
  • Create Account
  • Sign Out
  • My Account
  • NEWS
  • PRODUCTS
  • CONTRACTORS
  • ENGINEERS
  • RADIANT & HYDRONICS
  • INSIGHTS
  • MEDIA
  • RESOURCES
  • EMAGAZINE
  • SIGN UP!
cart
facebook instagram twitter linkedin youtube
  • CONTRACTORS
  • BATH & KITCHEN PRO
  • BUSINESS MANAGEMENT
  • HIGH EFFICIENCY HOMES
  • TECHNOLOGY
  • WATER TREATMENT
  • PMC COLUMNS
  • PMC COLUMNS
  • Dave Yates: Contractor’s Corner
  • John Siegenthaler: Hydronics Workshop
  • Kenny Chapman: The Blue Collar Coach
  • Matt Michel: Service Plumbing Pros
  • Scott Secor: Heating Perceptions
  • ENGINEERS
  • CONTINUING EDUCATION
  • DECARBONIZATION | ELECTRIFICATION
  • FIRE PROTECTION
  • GEOTHERMAL | SOLAR THERMAL
  • PIPING | PLUMBING | PVF
  • PME COLUMNS
  • PME COLUMNS
  • Christoph Lohr: Strategic Plumbing Insights
  • David Dexter: Plumbing Talking Points
  • James Dipping: Engineer Viewpoints
  • John Seigenthaler: Renewable Heating Design
  • Lowell Manalo: Plumbing Essentials
  • Misty Guard: Guard on Compliance
  • RADIANT & HYDRONICS
  • RADIANT COMFORT REPORT
  • THE GLITCH & THE FIX
  • INSIGHTS
  • CODES
  • GREEN PLUMBING & MECHANICAL
  • PROJECT PROFILES
  • COLUMNS
  • SPONSOR INSIGHTS
  • COLUMNS
  • Codes Corner
  • Natalie Forster: Editorial Opinion
  • Guest Editorial
  • MEDIA
  • PODCASTS
  • VIDEOS
  • WEBINARS
  • RESOURCES
  • INDUSTRY CALENDAR
  • DIRECTORIES
  • EBOOKS
  • PM BOOKSTORE
  • CE CENTER
  • MARKET RESEARCH
  • CLASSIFIEDS
  • EMAGAZINE
  • EMAGAZINE
  • ARCHIVE ISSUES
  • CONTACT
  • ADVERTISE
  • PME EMAGAZINE ARCHIVES
search
cart
facebook instagram twitter linkedin youtube
  • Sign In
  • Create Account
  • Sign Out
  • My Account
  • NEWS
  • PRODUCTS
  • CONTRACTORS
    • BATH & KITCHEN PRO
    • BUSINESS MANAGEMENT
    • HIGH EFFICIENCY HOMES
    • TECHNOLOGY
    • WATER TREATMENT
    • PMC COLUMNS
      • Dave Yates: Contractor’s Corner
      • John Siegenthaler: Hydronics Workshop
      • Kenny Chapman: The Blue Collar Coach
      • Matt Michel: Service Plumbing Pros
      • Scott Secor: Heating Perceptions
  • ENGINEERS
    • CONTINUING EDUCATION
    • DECARBONIZATION | ELECTRIFICATION
    • FIRE PROTECTION
    • GEOTHERMAL | SOLAR THERMAL
    • PIPING | PLUMBING | PVF
    • PME COLUMNS
      • Christoph Lohr: Strategic Plumbing Insights
      • David Dexter: Plumbing Talking Points
      • James Dipping: Engineer Viewpoints
      • John Seigenthaler: Renewable Heating Design
      • Lowell Manalo: Plumbing Essentials
      • Misty Guard: Guard on Compliance
  • RADIANT & HYDRONICS
    • RADIANT COMFORT REPORT
    • THE GLITCH & THE FIX
  • INSIGHTS
    • CODES
    • GREEN PLUMBING & MECHANICAL
    • PROJECT PROFILES
    • COLUMNS
      • Codes Corner
      • Natalie Forster: Editorial Opinion
      • Guest Editorial
    • SPONSOR INSIGHTS
  • MEDIA
    • PODCASTS
    • VIDEOS
    • WEBINARS
  • RESOURCES
    • INDUSTRY CALENDAR
    • DIRECTORIES
    • EBOOKS
    • PM BOOKSTORE
    • CE CENTER
    • MARKET RESEARCH
    • CLASSIFIEDS
  • EMAGAZINE
    • EMAGAZINE
    • ARCHIVE ISSUES
    • CONTACT
    • ADVERTISE
    • PME EMAGAZINE ARCHIVES
  • SIGN UP!
Columns

Water Heater Venting - Part II
Julius Ballanco, PE

By Julius Ballanco P.E., CPD
March 1, 2005
Follow the rules for venting or risk premature failure.

Last month, I addressed the changes in the classification of venting systems that impact the venting of a water heater. A standard tank-type, gas-fired water heater is a Category I appliance. Also in Category I are many residential furnaces and boilers. However, furnaces and some boilers use fan-assist combustion. As a result, this category of appliances is classified as Category I, Fan, whereas a water heater is Category I, Nat.

Combining a fan-assist combustion appliance with a natural burning combustion appliance requires attention to detail in sizing and installing the vent system. The fan-assist venting must match with the natural venting to allow the vent system to operate properly. Failure to follow the rules for venting can result in the premature failure of a vent system. This, of course, can lead to the escape of carbon monoxide into a building. A lethal dosage of carbon monoxide is 0.04 percent (not 4 percent, 0.04 percent) in the breathing atmosphere. That is a rather small quantity of CO. Hence it is imperative that you get the venting system right.

Before reviewing the venting of water heaters and fan-assist appliances, I should first recap the requirements for venting a water heater and a nonfan-assist Category I appliance. The old rule of thumb was the area of the largest vent plus 50 percent of the area of all the other vents connecting to the common vent is the minimum area of the common vent or Type B vent. This rule of thumb still would apply.

Another requirement was that the vent connector could extend 75 percent of the height of the chimney or vent. Again, this still would apply, assuming there is no fan-assist appliance connecting.

A major change occurred in exterior masonry chimneys. New tables were added to the Fuel Gas Code, which severely restricts the use of exterior masonry chimneys. An exterior masonry chimney is a chimney that has three sides exposed to the outside. You can no longer connect a single 40-, 50- or 75-gallon water heater to an exterior masonry chimney, unless the installation is in Southern California or South Florida.

What?! You read that correctly; you cannot connect one water heater to an exterior masonry chimney. What is required is for a Type B vent to be installed inside the masonry chimney.

This change reflects the concern for condensate attacking the inside wall of the masonry chimney. Since the venting of a water heater is minimal, there is not enough energy to heat up the wall of the masonry chimney to prevent condensation. This requirement does not pertain to inside masonry chimneys, only those chimneys on the exterior of the building.

Fan-Assist Rules

When you combine the venting of a water heater with a fan-assist appliance, throw out all of the old rules of thumb; they don't apply. The venting is completely different. First, the distance of the vent connector is greatly reduced. The distance from the water heater to the chimney or vent is 1 1/2 feet for every inch of vent connector. For example, a 4-inch vent connector can extend a maximum of 6 feet. This could mean that a water heater may have to be moved closer to the chimney or vent.

There are exceptions to this requirement when you reduce the capacity of the vent connector. The size of the vent connector must be determined by tables, not the water heater vent outlet. These tables can be found in the Fuel Gas Code, of which you should have a copy. When common-venting multiple appliances, you need to size each vent connector and the common vent by these tables.

The sizing is based on the input rating of the gas-fired appliance. Each vent connector size has three columns for sizing: two columns are for fan-assist appliances, and one for natural appliances. When sizing for a water heater, you only look at the NAT column. This column lists the maximum input rating permitted for a given vent connector size.

The sizing is not based on the appliance outlet. For example, if a 40-gallon water heater has a 3-inch draft hood and vent connection, it doesn't necessarily mean that a 3-inch vent connector is permitted. For most installations, a 3-inch vent connector must be increased to a minimum size of 4 inches. That is because the maximum input rating permitted on a 3-inch vent connector ranges from 26,000 to 42,000 Btu/hour, depending on the height of the vent and the rise of the vent connector. Since most 40-gallon water heaters are 40,000 Btu/hour or greater, you will find that most often the vent connector must be a minimum of 4 inches.

The maximum size (largest) permitted is always two diameters larger than the vent connector from the appliance. Hence, a 3-inch water heater vent outlet can have a 3-, 4- or 5-inch vent connector, depending on the tables, but not a 6-inch.

The combined vent size is regulated by the same table. At the bottom of the table, they list the maximum input rating for the common vent, depending on the type of appliances connecting. For a water heater and fan-assist appliance, the column would be FAN+NAT.

The maximum size of a vent is seven times the area of the small vent connector. Hence if there is a 3-inch vent connector, the largest vent size permitted would be 7 inches (actually 7.93 inches, but they don't make a vent that size). Again, there are exceptions to this when designed by engineering calculations.

If an offset of the vent is installed in the attic, this reduces the capacity of the vent. The reduction in capacity is 20 percent. If the table lists 100,000 Btu/hour as the maximum limit, that reduces to 80,000 Btu/hour when an offset is installed.

Some other rules that will impact water heaters: When installed in an unconditioned space, the vent connector must be double-walled. For example, a water heater installed in an attic or garage. Again, depending on the location (and climate), there are exceptions to this requirement.

When connecting a water heater and fan-assist appliance together, the majority of the time you will not be able to connect to a masonry chimney. When connecting to a masonry chimney, a liner is often required.

If you want to simplify your life, I would suggest buying one of the computer programs that sizes the vent system. One of the better programs is Elite Software. You can review a sample of the program at www.elitesoft.com.

Make sure you understand and install the venting system correctly. An incorrect installation can have deadly consequences.

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

Ballancojuliusvwhite 200

Julius Ballanco, P.E., CPD, F-ASPE, is president of J.B. Engineering and Code Consulting, P.C. in Munster, Ind. He can be reached at by email at jbengineer@aol.com.

Recommended Content

JOIN TODAY
to unlock your recommendations.

Already have an account? Sign In

  • Worker using the Milwaukee Tool SWITCH PACK drain cleaner

    Pipeline profits: Drain cleaning, pipe inspection create opportunities

    Drain cleaning and inspection services offer lucrative...
    Green Plumbing and Mechanical
    By: Nicole Krawcke
  • Uponor employee, Arturo Moreno

    The reinvestment in American manufacturing and training

    Plumbing & Mechanical Chief Editor Nicole Krawcke and...
    Plumbing News
    By: Nicole Krawcke and Natalie Forster
  • March 2024 Women in Plumbing hero image of woman engineer overlayed by circle of hexagon shapes with numbers from 1 to 10

    Celebrating 10 Influential Women in the Plumbing Industry

    Celebrating Women's History Month and Women in...
    Plumbing News
    By: Nicole Krawcke
close

1 COMPLIMENTARY ARTICLE(S) LEFT

Loader

Already a Registered User? Sign in now.

Subscribe For Free!
  • eNewsletters
  • Online Registration
  • Subscription Customer Service
  • eMagazine
  • Manage My Preferences

AI can boost efficiency and profitability for plumbing, HVAC contractors

AI can boost efficiency and profitability for plumbing, HVAC contractors

Bell & Gossett Illustrates Path to Net-zero at AHR Expo

Bell & Gossett Illustrates Path to Net-zero at AHR Expo

IPEX celebrates grand opening of new Florida distribution center

IPEX celebrates grand opening of new Florida distribution center

NIBCO Press Solutions

NIBCO Press Solutions

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to the Plumbing & Mechanical audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of Plumbing & Mechanical or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • J.J. Keller CMV vehicles on road
    Sponsored byJ. J. Keller & Associates, Inc.

    The dash cam game-changer for small business safety

Popular Stories

Underfloor heating installation with drain sewer hole in bathroom close up on water floor heating.

Using hydronics to leverage time-of-use electrical rates

Watts Nexa mobile image

Behind the Wall: Where smart plumbing gets smarter

Six tankless water heaters that feed the nutraceutical manufacturer’s operations.

How to deliver large volumes of hot water quickly and intermittently

PMCE Home-X April 29 Free Webinar: From Legacy to Leadership: Preparing Your Home Services Business for the Next Generation

Events

November 13, 2024

Future Proofing MEP: Navigating the 2026 High Efficiency Water Heating Standards

Join our deep dive into DOE’s new standards so you can future-proof your MEP practice.

EARN: 0.1 ASPE CEU; 1 AIA LU/HSW; 0.1 IACET CEU*; 1 PDH

View All Submit An Event

Poll

Will business be up or down in 2025?

Do you anticipate business in 2025 to be up or down in comparison to 2024?
View Results Poll Archive

Products

The Water Came To A Stop

The Water Came To A Stop

See More Products

Download the FREE Water Conservation, Quality & Safety eBook: Plumbing Trends Increasing Safe Water Availability

Related Articles

  • Julius Ballanco

    Mysteries of wet venting in bathrooms

    See More
  • It's The Solids That Run Away
    Julius Ballanco

    See More
  • Aging in place

    Julius Ballanco: Plumbing for aging in place

    See More
×

Keep your content unclogged with our newsletters!

Stay in the know on the latest plumbing & piping industry trends.

JOIN TODAY!
  • RESOURCES
    • Advertise
    • Contact Us
    • Directories
    • Store
    • Want More
    • Supply House Times
  • SIGN UP TODAY
    • Create Account
    • eMagazine
    • eNewsletter
    • Customer Service
    • Manage Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2025. All Rights Reserved BNP Media.

Design, CMS, Hosting & Web Development :: ePublishing

search
cart
facebook instagram twitter linkedin youtube
  • Sign In
  • Create Account
  • Sign Out
  • My Account
  • NEWS
  • PRODUCTS
  • CONTRACTORS
    • BATH & KITCHEN PRO
    • BUSINESS MANAGEMENT
    • HIGH EFFICIENCY HOMES
    • TECHNOLOGY
    • WATER TREATMENT
    • PMC COLUMNS
      • Dave Yates: Contractor’s Corner
      • John Siegenthaler: Hydronics Workshop
      • Kenny Chapman: The Blue Collar Coach
      • Matt Michel: Service Plumbing Pros
      • Scott Secor: Heating Perceptions
  • ENGINEERS
    • CONTINUING EDUCATION
    • DECARBONIZATION | ELECTRIFICATION
    • FIRE PROTECTION
    • GEOTHERMAL | SOLAR THERMAL
    • PIPING | PLUMBING | PVF
    • PME COLUMNS
      • Christoph Lohr: Strategic Plumbing Insights
      • David Dexter: Plumbing Talking Points
      • James Dipping: Engineer Viewpoints
      • John Seigenthaler: Renewable Heating Design
      • Lowell Manalo: Plumbing Essentials
      • Misty Guard: Guard on Compliance
  • RADIANT & HYDRONICS
    • RADIANT COMFORT REPORT
    • THE GLITCH & THE FIX
  • INSIGHTS
    • CODES
    • GREEN PLUMBING & MECHANICAL
    • PROJECT PROFILES
    • COLUMNS
      • Codes Corner
      • Natalie Forster: Editorial Opinion
      • Guest Editorial
    • SPONSOR INSIGHTS
  • MEDIA
    • PODCASTS
    • VIDEOS
    • WEBINARS
  • RESOURCES
    • INDUSTRY CALENDAR
    • DIRECTORIES
    • EBOOKS
    • PM BOOKSTORE
    • CE CENTER
    • MARKET RESEARCH
    • CLASSIFIEDS
  • EMAGAZINE
    • EMAGAZINE
    • ARCHIVE ISSUES
    • CONTACT
    • ADVERTISE
    • PME EMAGAZINE ARCHIVES
  • SIGN UP!