• Sign In
  • Create Account
  • Sign Out
  • My Account
  • NEWS
  • PRODUCTS
  • CONTRACTORS
  • ENGINEERS
  • RADIANT & HYDRONICS
  • INSIGHTS
  • MEDIA
  • RESOURCES
  • EMAGAZINE
  • SIGN UP!
cart
facebook instagram twitter linkedin youtube
  • CONTRACTORS
  • BATH & KITCHEN PRO
  • BUSINESS MANAGEMENT
  • HIGH EFFICIENCY HOMES
  • TECHNOLOGY
  • WATER TREATMENT
  • PMC COLUMNS
  • PMC COLUMNS
  • Dave Yates: Contractor’s Corner
  • John Siegenthaler: Hydronics Workshop
  • Kenny Chapman: The Blue Collar Coach
  • Matt Michel: Service Plumbing Pros
  • Scott Secor: Heating Perceptions
  • ENGINEERS
  • CONTINUING EDUCATION
  • DECARBONIZATION | ELECTRIFICATION
  • FIRE PROTECTION
  • GEOTHERMAL | SOLAR THERMAL
  • PIPING | PLUMBING | PVF
  • PME COLUMNS
  • PME COLUMNS
  • Christoph Lohr: Strategic Plumbing Insights
  • David Dexter: Plumbing Talking Points
  • James Dipping: Engineer Viewpoints
  • John Seigenthaler: Renewable Heating Design
  • Lowell Manalo: Plumbing Essentials
  • Misty Guard: Guard on Compliance
  • RADIANT & HYDRONICS
  • RADIANT COMFORT REPORT
  • THE GLITCH & THE FIX
  • INSIGHTS
  • CODES
  • GREEN PLUMBING & MECHANICAL
  • PROJECT PROFILES
  • COLUMNS
  • SPONSOR INSIGHTS
  • COLUMNS
  • Codes Corner
  • Natalie Forster: Editorial Opinion
  • Guest Editorial
  • MEDIA
  • PODCASTS
  • VIDEOS
  • WEBINARS
  • RESOURCES
  • INDUSTRY CALENDAR
  • DIRECTORIES
  • EBOOKS
  • PM BOOKSTORE
  • CE CENTER
  • MARKET RESEARCH
  • CLASSIFIEDS
  • EMAGAZINE
  • EMAGAZINE
  • ARCHIVE ISSUES
  • CONTACT
  • ADVERTISE
  • PME EMAGAZINE ARCHIVES
search
cart
facebook instagram twitter linkedin youtube
  • Sign In
  • Create Account
  • Sign Out
  • My Account
  • NEWS
  • PRODUCTS
  • CONTRACTORS
    • BATH & KITCHEN PRO
    • BUSINESS MANAGEMENT
    • HIGH EFFICIENCY HOMES
    • TECHNOLOGY
    • WATER TREATMENT
    • PMC COLUMNS
      • Dave Yates: Contractor’s Corner
      • John Siegenthaler: Hydronics Workshop
      • Kenny Chapman: The Blue Collar Coach
      • Matt Michel: Service Plumbing Pros
      • Scott Secor: Heating Perceptions
  • ENGINEERS
    • CONTINUING EDUCATION
    • DECARBONIZATION | ELECTRIFICATION
    • FIRE PROTECTION
    • GEOTHERMAL | SOLAR THERMAL
    • PIPING | PLUMBING | PVF
    • PME COLUMNS
      • Christoph Lohr: Strategic Plumbing Insights
      • David Dexter: Plumbing Talking Points
      • James Dipping: Engineer Viewpoints
      • John Seigenthaler: Renewable Heating Design
      • Lowell Manalo: Plumbing Essentials
      • Misty Guard: Guard on Compliance
  • RADIANT & HYDRONICS
    • RADIANT COMFORT REPORT
    • THE GLITCH & THE FIX
  • INSIGHTS
    • CODES
    • GREEN PLUMBING & MECHANICAL
    • PROJECT PROFILES
    • COLUMNS
      • Codes Corner
      • Natalie Forster: Editorial Opinion
      • Guest Editorial
    • SPONSOR INSIGHTS
  • MEDIA
    • PODCASTS
    • VIDEOS
    • WEBINARS
  • RESOURCES
    • INDUSTRY CALENDAR
    • DIRECTORIES
    • EBOOKS
    • PM BOOKSTORE
    • CE CENTER
    • MARKET RESEARCH
    • CLASSIFIEDS
  • EMAGAZINE
    • EMAGAZINE
    • ARCHIVE ISSUES
    • CONTACT
    • ADVERTISE
    • PME EMAGAZINE ARCHIVES
  • SIGN UP!
Columns

Ballanco's Plumbing Forum

By Julius Ballanco P.E., CPD
May 31, 2000
Answers to the Questions You’ve Been Asking

Question: I’m confused about the backflow protection requirements for fire sprinkler systems. What type of device do I have to install?

Answer: You’re not the only one confused. If there is one area that plumbing codes, as well as building and fire codes disagree on, it is backflow protection for fire sprinkler systems. The required protection ranges from a reduced pressure principle backflow preventer to a double check valve assembly to a single check with a flow alarm. Unfortunately, the difference in the codes normally depends on the political strength of the different groups fighting over the code, not the technical reasoning.

It has been well documented that sprinkler systems piped in black steel pipe do not contain potable water. The entire concept of backflow protection is to protect the potable water supply against contamination from a non-potable supply. Hence, it would only seem logical to have a backflow preventer isolating the potable supply from the fire sprinkler system. I personally believe that a backflow preventer is necessary.

While a reduced pressure principle backflow preventer provides the highest level of backflow protection, it has one major drawback for a fire sprinkler system. When there is a pressure differential between the supply inlet and the downstream pressure that exceeds 2 psi, the valve opens the intermediate chamber and dumps water. Well, in a sprinkler system this can occur several times during the day. Since there is no flow in the sprinkler system, any time the inlet pressure lowers by 2 psi, the valve spits water. (The valve is doing its job.)

Because of this problem, double check valve assemblies were specifically developed for the fire sprinkler industry. The double check valve assembly is not as high a level of protection, however, it provides adequate protection against backflow since the fire sprinkler system is stagnant. If the double check valve assembly is inspected and tested annually, there should be no problem with the valve serving as the backflow preventer. The only exception (in my mind) is when chemicals are added to the sprinkler system. Then, an RP should be installed.

If you install a reduced pressure principle backflow preventer, then I would advise you take the appropriate steps to prevent the valve from constantly dumping water. What I do is install a single check valve ahead of the reduced pressure principle backflow preventer. The single check can help to fake out the backflow preventer to not realize that there has been a pressure drop in the supply piping. Many plumbers are shocked at how effective the installation of the single check is.

Every commercial sprinkler system is required by NFPA to have a check valve and flow alarm. However, these devices, in series, should never be considered as backflow protection. This installation is like playing Russian roulette with your water supply system. Like those who oppose backflow protection on sprinkler systems, you may get lucky and nothing will ever happen. Then again, you may be unlucky.

The bottom line is to check with the local jurisdiction regarding requirements for backflow protection to a fire sprinkler system. Many codes have changed in recent years adding requirements for backflow protection.

Question: If an existing fire sprinkler system only has a single check valve with a water flow alarm should I install a backflow preventer?

Answer: Not necessarily. I know how, sometimes, I can spout off about backflow in the first question and then renege on protection for existing systems. Sprinkler systems are calculated based on pressure loss. The systems have a history of being designed very tightly. Hence, any additional loss of pressure may cause the system to be out of specification.

Before any backflow preventer is installed on an existing system, an engineer must run the calculations to see if the valve will maintain the pressure requirements. If the valve results in the pressure being inadequate for a sprinkler system, then modifications to the system must be made before a backflow preventer is installed. You certainly don’t need a fire in the building with the sprinkler system failing because of a backflow preventer. Lawyers would have a field day with your company.

Question: I thought I knew how to calculate the pressure in a water piping system but every time I check the pressure against my calculations, I’m off by quite a few psi. What did I do wrong?

Answer: Probably nothing. If the pressure you measure is the same as the pressure you calculated, then you probably did something wrong. Every water pipe sizing method has had engineering input. Speaking as an engineer, all engineers are wimps. As soon as they figure out the right way to do something, they add a fudge factor. Of course, they call it a factor of safety. That sounds better than what it really is — a fudge factor.

The pipe is assigned a roughness coefficient. Every roughness coefficient is too conservative. The pipe is smoother, hence, there would be less pressure loss. The system is designed for peak demand. That means a huge amount of fixtures operating at the same time. That usually never occurs in the life of the system.

Many sizing methods have you deduct 0.5 psi for every foot you raise the water in height. For example, in a three–story building with the water piped 30 feet, you deduct 15 psi. In reality, the pressure loss is only 0.433, not 0.5. It is just easier to use one half instead of 0.433. Thus, for that 30 feet in height, the pressure loss would be 12.99 or 13 psi, not 15 psi.

Another difference is the flow rate. You may calculate a flow rate of 2.5 gpm out of the shower head. If there is a flow restrictor, the flow rate may only be 2 gpm. That changes the velocity, pressure loss, etc. So don’t get too excited if the pressure is not the same as what you calculated.

Question: Will I get thrown in jail if I install a 3.5 gpf water closet that I have in my shop?

Answer: No. The federal law only prevents manufacturers (and others) from making, or importing, water closets that flush more than 1.6 gpf. If you have a leftover, you are still permitted to use the fixture until you run out of them. However, many plumbing codes have long since required 1.6 gpf water closets. So, while you are not violating federal law, you may be violating the local plumbing code.

If you happen to see a 3.5 gpf water closet in a supply house or do-it-yourself place, I would check the date stamp very carefully. That water closet better have been made last year or earlier. If not, you are purchasing an illegal plumbing fixture, according to the feds. It is better not to mess around with black market water closets. I would recommend that you find a quality 1.6 flusher. There are many out there.

Question: Can a dishwasher connect directly into a garbage disposal unit? They all have the connection, but I’ve often been told that I can’t use it.

Answer: There is no technical reason for not connecting a dishwasher to a garbage disposer. That is how I hooked up the dishwasher in my house. The problem is that many plumbing codes prohibit this installation.

The codes that prohibit the dishwasher from connecting to the garbage disposer will give you all sorts of reasons for prohibiting the practice. None of the reasons are valid. If there were a problem with the installation, I can assure you that the manufacturers would not provide the knock out in the garbage disposer.

If your plumbing code prohibits the installation, get the code changed.

Question: I have one home where there is a tremendous bang when the sump pump turns on. The owner put in a super-sized sump pump but I can’t find anything wrong with the installation. What’s happening?

Answer: Water hammer! What everybody forgets is that water hammer (or hydraulic shock) occurs whenever there is an instantaneous change in velocity. The flow does not have to shut off completely for water hammer to occur.

If you check the installation, you probably will find a fitting that impedes the flow of water. With the super-sized pump, the water can be discharging at a rate of up to 10–12 feet per second. That’s pretty fast. When the flow hits a non-directional fitting, it slows the flow instantly to about 2–3 feet per second. The result is a hydraulic shock or water hammer.

Of course, you wouldn’t put a water hammer arrestor on a sump pump discharge line. But, there are ways to eliminate the hydraulic shock. Either slow the velocity of flow down, or prevent the flow velocity from being changed instantly. You can slow the velocity of flow by either increasing the size of the discharge pipe or by reducing the size of the sump pump. You can prevent instantaneous change in velocity by installing directional fittings at all intersections. A wye is better than a tee fitting for a sump discharge pipe.

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

Ballancojuliusvwhite 200

Julius Ballanco, P.E., CPD, F-ASPE, is president of J.B. Engineering and Code Consulting, P.C. in Munster, Ind. He can be reached at by email at jbengineer@aol.com.

Recommended Content

JOIN TODAY
to unlock your recommendations.

Already have an account? Sign In

  • Worker using the Milwaukee Tool SWITCH PACK drain cleaner

    Pipeline profits: Drain cleaning, pipe inspection create opportunities

    Drain cleaning and inspection services offer lucrative...
    Green Plumbing and Mechanical
    By: Nicole Krawcke
  • Uponor employee, Arturo Moreno

    The reinvestment in American manufacturing and training

    Plumbing & Mechanical Chief Editor Nicole Krawcke and...
    Plumbing News
    By: Nicole Krawcke and Natalie Forster
  • March 2024 Women in Plumbing hero image of woman engineer overlayed by circle of hexagon shapes with numbers from 1 to 10

    Celebrating 10 Influential Women in the Plumbing Industry

    Celebrating Women's History Month and Women in...
    Plumbing News
    By: Nicole Krawcke
close

1 COMPLIMENTARY ARTICLE(S) LEFT

Loader

Already a Registered User? Sign in now.

Subscribe For Free!
  • eNewsletters
  • Online Registration
  • Subscription Customer Service
  • eMagazine
  • Manage My Preferences

Bell & Gossett Illustrates Path to Net-zero at AHR Expo

Bell & Gossett Illustrates Path to Net-zero at AHR Expo

AI can boost efficiency and profitability for plumbing, HVAC contractors

AI can boost efficiency and profitability for plumbing, HVAC contractors

NIBCO Press Solutions

NIBCO Press Solutions

IPEX celebrates grand opening of new Florida distribution center

IPEX celebrates grand opening of new Florida distribution center

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to the Plumbing & Mechanical audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of Plumbing & Mechanical or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • J.J. Keller CMV vehicles on road
    Sponsored byJ. J. Keller & Associates, Inc.

    The dash cam game-changer for small business safety

Popular Stories

Underfloor heating installation with drain sewer hole in bathroom close up on water floor heating.

Using hydronics to leverage time-of-use electrical rates

Watts Nexa mobile image

Behind the Wall: Where smart plumbing gets smarter

Six tankless water heaters that feed the nutraceutical manufacturer’s operations.

How to deliver large volumes of hot water quickly and intermittently

PMCE Home-X April 29 Free Webinar: From Legacy to Leadership: Preparing Your Home Services Business for the Next Generation

Events

November 13, 2024

Future Proofing MEP: Navigating the 2026 High Efficiency Water Heating Standards

Join our deep dive into DOE’s new standards so you can future-proof your MEP practice.

EARN: 0.1 ASPE CEU; 1 AIA LU/HSW; 0.1 IACET CEU*; 1 PDH

View All Submit An Event

Poll

Will business be up or down in 2025?

Do you anticipate business in 2025 to be up or down in comparison to 2024?
View Results Poll Archive

Products

The Water Came To A Stop

The Water Came To A Stop

See More Products

Download the FREE Water Conservation, Quality & Safety eBook: Plumbing Trends Increasing Safe Water Availability

Related Articles

  • Aging in place

    Julius Ballanco: Plumbing for aging in place

    See More
  • It's The Solids That Run Away
    Julius Ballanco

    See More
  • Plumbing Design Of Residential Sprinklers

    See More
×

Keep your content unclogged with our newsletters!

Stay in the know on the latest plumbing & piping industry trends.

JOIN TODAY!
  • RESOURCES
    • Advertise
    • Contact Us
    • Directories
    • Store
    • Want More
    • Supply House Times
  • SIGN UP TODAY
    • Create Account
    • eMagazine
    • eNewsletter
    • Customer Service
    • Manage Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2025. All Rights Reserved BNP Media.

Design, CMS, Hosting & Web Development :: ePublishing

search
cart
facebook instagram twitter linkedin youtube
  • Sign In
  • Create Account
  • Sign Out
  • My Account
  • NEWS
  • PRODUCTS
  • CONTRACTORS
    • BATH & KITCHEN PRO
    • BUSINESS MANAGEMENT
    • HIGH EFFICIENCY HOMES
    • TECHNOLOGY
    • WATER TREATMENT
    • PMC COLUMNS
      • Dave Yates: Contractor’s Corner
      • John Siegenthaler: Hydronics Workshop
      • Kenny Chapman: The Blue Collar Coach
      • Matt Michel: Service Plumbing Pros
      • Scott Secor: Heating Perceptions
  • ENGINEERS
    • CONTINUING EDUCATION
    • DECARBONIZATION | ELECTRIFICATION
    • FIRE PROTECTION
    • GEOTHERMAL | SOLAR THERMAL
    • PIPING | PLUMBING | PVF
    • PME COLUMNS
      • Christoph Lohr: Strategic Plumbing Insights
      • David Dexter: Plumbing Talking Points
      • James Dipping: Engineer Viewpoints
      • John Seigenthaler: Renewable Heating Design
      • Lowell Manalo: Plumbing Essentials
      • Misty Guard: Guard on Compliance
  • RADIANT & HYDRONICS
    • RADIANT COMFORT REPORT
    • THE GLITCH & THE FIX
  • INSIGHTS
    • CODES
    • GREEN PLUMBING & MECHANICAL
    • PROJECT PROFILES
    • COLUMNS
      • Codes Corner
      • Natalie Forster: Editorial Opinion
      • Guest Editorial
    • SPONSOR INSIGHTS
  • MEDIA
    • PODCASTS
    • VIDEOS
    • WEBINARS
  • RESOURCES
    • INDUSTRY CALENDAR
    • DIRECTORIES
    • EBOOKS
    • PM BOOKSTORE
    • CE CENTER
    • MARKET RESEARCH
    • CLASSIFIEDS
  • EMAGAZINE
    • EMAGAZINE
    • ARCHIVE ISSUES
    • CONTACT
    • ADVERTISE
    • PME EMAGAZINE ARCHIVES
  • SIGN UP!