Real-World Radiant Energy Savings
by Larry Drake
June 1, 2007
 |
| Winter hits a nice, warm radiant house. |
|
How my own home’s energy use can help build an
industry-wide database to prove radiant efficiency.
Ask anybody in the radiant floor heating
business, and they will tell you radiant floor heating can save energy.
Unfortunately, ask anybody in the radiant floor heating business, and they will
tell you hard data on actual energy savings is hard to come by.
We can certainly draw an easy, fair conclusion between a specific boiler’s
efficiency to a specific furnace’s efficiency by comparing the Department of
Energy’s Annual Fuel Utilization Efficiency (AFUE) rating. But radiant heating
is more than just a heat-generating system, it’s also a heat distribution
method. Just how can you compare water pipes in the floor to hot air ductwork
and registers?
To complicate matters even further, people don’t react to the various heat
delivery systems in the same way. Left to their own comfort choices, people
will set their thermostats differently in a radiant system than they will in a
forced air environment. They will live differently in the space as well, frequenting
different parts of the house more often depending on the heat delivery system.
Add on top of that the variations in building construction and design, and how
the heat delivery systems react to the building envelope, and an
apples-to-apples comparison becomes difficult at best.
So what is the answer to acquiring hard data to substantiate the common claims
that radiant heating is more energy-efficient than forced air? A single test chamber
or test house will only provide data for that particular configuration. In
fact, a number of those types of studies have been done over the past 50 years
with varying results.
What’s needed is a large number and a wide variety of buildings to build a
reasonably comparative database. I believe the Radiant Panel Association has
the ability to do just that through its members. By providing a data collection
point, we can build a database of structures that have been converted from
conventional heating to radiant heating, buildings that have a history of
before and after. With enough input, we can make reasonable comparisons and
draw substantiated conclusions.
My Own Data
 |
|
The
Quietside 90 percent AFUE-rated boiler that was installed with the radiant
heating system.
|
|
What convinced me that this scenario is possible
was the retrofit and subsequent data collected on my own home. In the summer of
2006, I removed the entire forced-air heating system and replaced it with a
radiant floor heating system. We had purchased the 30-year-old home on a crawl
space four years ago with the intent of converting it to radiant. After living
in homes with radiant heat for 20 years, it meant moving back into forced air
for a while. As with most projects, it took several years longer to get around
to it than I had expected.
|
|
| Figure 1: After the radiant floor installation, energy use remained the same even though a much colder winter was experienced. |
|
The good news is, not only did I get a big dose
of why radiant is so much more comfortable than forced air, it gave me the data
I needed to make a real-world comparison. I gathered up all my heating bills
since 2003 and did a detailed comparison. I can truly say that radiant floor
heating has saved us 9 percent in utility use, and I can back it up with
facts.
In doing a comparison of this sort, you cannot simply compare this year’s
utility bills with last year’s or the year before. Obviously, annual weather plays
a big part in how much energy is used.
The best yardstick we have for weather is the “degree day.” Degree days are
tracked by the National Climatic Data Center and are reported for most cities
in the United States. (For a free report, visit www.EnergyCAP.com.) A degree day is defined as a “deviation of
one degree temperature for one day from an arbitrary standard, usually the
long-term average temperature for a place.”
ASHRAE uses 65 degrees F as the outside temperature below which a structure
will require heat. In other words, if we use the ASHRAE-specified 65 degrees F,
and the average temperature of a particular winter’s day is 10 degrees F, the
difference would be 55 degrees, or 55 degree days. The colder it is, the more
degree days. We can add up all the degree days for a winter and compare them to
the degree days of the same period for a previous winter.
I tracked degree days from October through March over four years. As you can see
by Figure 1, last winter was significantly colder (more degree days) than the
three previous winters, but the amount of gas in “therms” used was about the
same. A therm is equal to 100,000 Btus. This is a utility company’s measurement
for gas used.
|
|
| Figure 2: A substantial drop in energy use can be seen after the forced-air system was replaced with a radiant system. |
|
To get a true comparison of utility usage, I
divided the amount of therms by the degree days to find therms per degree day.
Figure 2 shows that the therms per degree day fell off significantly after the
radiant system was installed in 2006. As an interesting side note, the drop
shown after 2003 was a result of replacing old windows and roof with new that
year.
But the picture the chart paints needed some adjustment to make it accurate.
Figure 3 illustrates what happened to the electric utility use, since the new
boiler now heats the domestic hot water originally handled with an electric
water heater. Since Figure 2 initially reflected all gas used, the energy expended
on heating domestic hot water in 2006-2007 was subtracted from the total to
reflect the actual amount of gas used for space heating alone.
|
|
| Figure 3: The new gas boiler also picked up the domestic water heating load from the old electric water heater as seen in this chart. |
|
This data shows that I did, indeed, save 9
percent on my utility use. But was that a result of the radiant heating system
or some other factor? The same two people live in the house. No insulation or
other energy-saving features had been added for the past three years and our
lifestyle had not changed.
What could be significant is the change in the heating plant itself. If we had
replaced an old, standing pilot light, naturally ventilated furnace with a new,
high-efficiency condensing boiler; that alone could account for the savings. As
it is, the removed furnace was a five-year-old, high-efficiency, fully
condensing unit with insulated ductwork. The 92 percent AFUE rating on the
Amana furnace is very nearly the same as 90 percent AFUE rating on the new
Quietside boiler that now hangs on the wall. Had there been a significant
difference, those differences could have been calculated and taken into
consideration.
As it stands, I can say with a high degree of confidence that the installation
of a radiant heat distribution system accounts for the energy savings.
Savings
 |
| The 4-zone module. |
|
You may be thinking that 9 percent is not a lot
of savings, but consider this: When living with forced air and a single
thermostat, the only warm place in the house was the living room nearest the
thermostat.
The back rooms were always chilly to cold. The master bathroom was as much as
10 degrees colder than the living room. The great room, where we spend most of
our time, has three outside walls, a fireplace and lots of windows. It was
always cold, no matter where the thermostat was set. The bed in the guest room
was piled high with blankets to keep our visitors warm.
 |
| The ductwork removed from the crawlspace. |
|
Sweaters and slippers were required in most of
the house even when the thermostat was turned up. Now, with three zones and
uniform radiant heating, all the rooms are comfortable. If we set the
thermostats down to the bone-chilling temperature those fringe rooms used to be
at, we would undoubtedly see a lot more savings.
Not only that, but I also installed gas logs in the original wood-burning
fireplace. Now we sit watching the
flames dance over ceramic logs while 80 percent of that heat goes up the
chimney. That’s about 60,000 Btus per hour wasted up the stack just to add a
nice ambience to the family room on a snowy day. We gain the warmth, comfort
and aesthetics and still save 9 percent. Not a bad deal.
 |
| Heat transfer plates applied to the underside of
the subfloor in the crawl space. |
|
A section has been set up at www.RadiantPanelAssociation.org to guide contractors in collecting data on
retrofit systems and reporting that data online. Information on buildings that
were once heated with forced air or baseboard can be entered on the site. The
straightforward questions are easy to answer. Utility bills and some building
and system info are required.
The RPA will compile the information, input the appropriate degree day data and
perform the necessary calculations. The result will be an energy comparison for
each structure. The results will be fed back to the submitting contractor and
included in a growing database on the RPA Web site. The database will be made
available to RPA members and summarized for use in the trade and consumer
press.
It starts with a single home, but with each building added, more knowledge will
be gained. As this program grows with acquired data, confidence in the radiant
heating industry also will grow. This could be just the tool the industry has
been asking for to confirm what we have experienced and know to be true.
|